{"product_id":"endress-hauser-dosimag-electromagnetic-flowmeter","title":"Endress+Hauser Dosimag Electromagnetic Flowmeter","description":"\u003cstyle\u003e#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:587px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin-top:0;margin-left:0;width:750px;height:587px}#detail_decorate_root .magic-3{width:446px}#detail_decorate_root .magic-4{overflow:hidden;width:446px;height:486.43733333333336px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-5{margin-top:-16.650666666666666px;margin-left:-44.00533333333333px;width:519px;height:519px}#detail_decorate_root .magic-6{width:300px;display:flex;flex-direction:column;margin-right:0;margin-left:4px}#detail_decorate_root .magic-7{font-size:20px}#detail_decorate_root .magic-8{vertical-align:top}#detail_decorate_root .magic-9{vertical-align:top;display:inline-block;padding-right:4px;width:50%;box-sizing:border-box;margin-bottom:-4px;padding-left:4px;margin-top:-4px}#detail_decorate_root .magic-10{padding:0;margin:0}#detail_decorate_root .magic-11{padding:0;margin:0;color:#333;font-size:14px;line-height:20px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-12{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-13{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-14{font-size:18px}#detail_decorate_root .magic-15{white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-16{overflow:hidden;width:750px;height:75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-17{margin-top:0;margin-left:0;width:750px;height:75px}#detail_decorate_root .magic-18{width:750px;border-collapse:collapse}#detail_decorate_root .magic-19{min-height:28px;padding:5px 10px;width:259px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-20{min-height:28px;padding:5px 10px;width:442px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-21{min-height:28px;padding:5px 10px;width:258.901px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-22{min-height:28px;padding:5px 10px;width:441.906px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-23{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-24{overflow:hidden;width:750px;height:1078px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-25{margin-top:0;margin-left:0;width:750px;height:1078px}#detail_decorate_root .magic-26{overflow:hidden;width:750px;height:814px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-27{margin-top:0;margin-left:0;width:750px;height:814px}#detail_decorate_root .magic-28{overflow:hidden;width:750px;height:758px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-29{margin-top:0;margin-left:0;width:750px;height:758px}#detail_decorate_root .magic-30{overflow:hidden;width:750px;height:583px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-31{margin-top:0;margin-left:0;width:750px;height:583px}#detail_decorate_root .magic-32{overflow:hidden;width:750px;height:893px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-33{margin-top:0;margin-left:0;width:750px;height:893px}#detail_decorate_root .magic-34{overflow:hidden;width:750px;height:675px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-35{margin-top:0;margin-left:0;width:750px;height:675px}#detail_decorate_root .magic-36{overflow:hidden;width:750px;height:76px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-37{margin-top:0;margin-left:0;width:750px;height:76px}#detail_decorate_root .magic-38{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}\u003c\/style\u003e\n\u003cdiv data-magic-global=\"%7B%22bizId%22%3A2217607044645%2C%22pageId%22%3A200110072317%2C%22siteId%22%3A10100897032%7D\" id=\"detail_decorate_root\"\u003e\n\u003cdiv module-id=\"201243750666\" module-title=\"detailSingleImage\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201243750667\" module-title=\"detailHorizontalImageText\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"eh-upid-header--description eh-p-t-2 eh-font-metrics--18-24\"\u003eFlowmeter with hygienic design, highest repeatability and an ultra-compact sensor\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eMax. measurement error ±0.25 % o.r. ± 1 to 4 m\/s (3.3 to 13 ft\/s)\u003cbr\u003e±0.5 % o.r. ± 1 mm\/s (0.04 in\/s)\u003cbr\u003e±5 % o.r. Measuring range 0.14 to 1.66 l\/s (0.035 to 0.44 gal\/s) Medium temperature range Seal material EPDM: –20 to +130 °C (–4 to +266 °F)\u003cbr\u003eSeal material Silicone: –20 to +130 °C (–4 to +266 °F)\u003cbr\u003eSeal material Viton: 0 to +150 °C (+32 to +302 °F) Max. process pressure PN 16 Wetted materials Liner: PFA\u003cbr\u003eElectrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,\u003cbr\u003ePlatinum\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201243750668\" module-title=\"detailDoubleTitleParagraph\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eApplication\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eDosimag is specially designed for filling and bottling applications of conductive liquids. It measures volume directly. Designed for applications where space is a premium, Dosimag will be the preferred choice for system integrators, skid builders and equipment manufacturers.\u003cbr\u003e\u003cbr\u003e* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity\u003cbr\u003e* For demanding dosing and filling applications.\n\u003cdiv\u003e\n\u003cbr\u003eDevice properties\u003cbr\u003e* Wetted materials CIP, SIP cleanable\u003cbr\u003e* Nominal diameter: DN 4 to 25 (1\/8 to 1\")\u003cbr\u003e* Measuring device conform to FDA\u003cbr\u003e* Pulse\/frequency\/switch output, Modbus RS485\u003cbr\u003e* Custody transfer approvals (MID, NTEP)\u003cbr\u003e* Excellent and easy cleanable transmitter \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e* High process safety – high measuring accuracy and repeatability in shortest filling time\u003cbr\u003e* Energy-saving flow measurement – no pressure loss due to cross-section constriction\u003cbr\u003e* Maintenance-free – no moving parts\u003cbr\u003e* Versatile and time-saving wiring – plug connector\u003cbr\u003e* Industry-optimized – ultra-compact design\u003cbr\u003e* For hygiene requirements – stainless steel housing\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201243750669\" module-title=\"detailSingleImage\" render=\"true\"\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201243750670\" module-title=\"detailTableHorizontal\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eModel Number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProline Promag W 300\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMeasuring principle\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eElectromagnetic \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProduct headline\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eFlowmeter with hygienic design, highest repeatability and an ultra-compact sensor. \u003cbr\u003eFor demanding dosing and filling applications.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSensor features\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eHigh process safety – high measuring accuracy and repeatability in shortest filling time. Energy‐saving flow measurement – no \u003cbr\u003epressure loss due to cross section constriction. Maintenance‐free – no moving parts. \u003cbr\u003eWetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (¹⁄₈ to 1\"). Measuring device conform to FDA.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eTransmitter features\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eVersatile and time-saving wiring – plug connector. Industry-optimized – ultra-compact design. For hygienic requirements – \u003cbr\u003estainless steel housing. \u003cbr\u003ePulse\/frequency\/switch output, Modbus RS485. Custody transfer approvals (MID, NTEP). Excellent, easily cleanable transmitter.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eNominal diameter range\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eDN 4 (⁵⁄₃₂\"), 8 (⁵⁄₁₆\"), 15 (½\"), 25 (1\")\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eWetted materials\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eLiner: PFA \u003cbr\u003eElectrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum, \u003cbr\u003ePlatinum\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMeasured variables\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eVolume flow\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMax. measurement error\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e±0.25 % o.r. ± 1 to 4 m\/s (3.3 to 13 ft\/s) \u003cbr\u003e±0.5 % o.r. ± 1 mm\/s (0.04 in\/s) \u003cbr\u003e±5 % o.r.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMeasuring range\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e0.14 to 1.66 l\/s (0.035 to 0.44 gal\/s)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMax. process pressure\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePN 16\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMedium temperature range\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSeal material EPDM: –20 to +130 °C (–4 to +266 °F) \u003cbr\u003eSeal material Silicone: –20 to +130 °C (–4 to +266 °F) \u003cbr\u003eSeal material Viton: 0 to +150 °C (+32 to +302 °F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eAmbient temperature range\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e–40 to +60 °C (–40 to +140 °F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSensor housing material\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e1.4308 (304)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eTransmitter housing material\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e1.4308 (304)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eDegree of protection\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eIP66\/67, type 4X enclosure\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eDisplay\/Operation\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eNo local Operation \u003cbr\u003eConfiguration via operating tools possible\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eOutputs\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePulse\/frequency\/switch output (passive)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eInputs\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eNone\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eDigital communication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eModbus RS485\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePower supply\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eDC 20 to 30 V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eHazardous area approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eATEX, IECEx, cCSAus\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProduct safety\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCE\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMetrological approvals and certificates\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCalibration performed on accredited calibration facilities (acc.to ISO\/IEC 17025) \u003cbr\u003eNTEP\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMaterial certificates\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e\n\u003cbr\u003e3.1 material\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eHygienic approvals and certificates\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSanitary approval: 3-A, EHEDG, seals acc. to FDA\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201243750680\" module-title=\"detailTextContent\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020363935961,"sku":null,"price":2500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_Dosimag_Electromagnetic_Flowmeter.png?v=1771970540","url":"https:\/\/www.aloinfousa.com.mx\/en\/products\/endress-hauser-dosimag-electromagnetic-flowmeter","provider":"aloinfousa.com","version":"1.0","type":"link"}