{"product_id":"endresshauser-temperature-sensor-itherm-moduline-tm101","title":"Endress+hauser Temperature Sensor iTHERM ModuLine TM101","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eEndress+hauser iTHERM ModuLine TM101 TEMPERATURE SENSOR \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/wPtjmhc2IIA?si=Xu8twh8T_YjRHom2\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eApplication\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eBasic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert for use in non-hazardous areas. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.\u003c\/p\u003e\n\u003cp\u003e*Wide range of applications *Measuring range: -50 to +650 °C (-58 to +1202 °F) \u003c\/p\u003e\n\u003cp\u003e*Pressure range: up to 50 bar (725 psi)\u003c\/p\u003e\n\u003cp\u003e*Protection class: up to IP68\u003c\/p\u003e\n\u003cp\u003e*For use in non-hazardous areas\u003c\/p\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e*Excellent value for money and fast global delivery \u003c\/p\u003e\n\u003cp\u003e*User-friendly product selection, smart design for easy maintenance\u003c\/p\u003e\n\u003cp\u003e*Wide range of process connections\u003c\/p\u003e\n\u003cp\u003e*Bluetooth® connectivity (optional)\u003c\/p\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification \u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ctable height=\"803\" style=\"width: 92.4789%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eMeasuring principle\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e\u003cspan\u003eResistance Temperature Detector\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eCharacteristic \/ Application\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003eBasic technologie\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emetric style\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003euniversal range of application\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003edirect process contact\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eThermowell \/ protection tube\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e\u003cspan\u003ewithout, direct process contact\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eInsert \/ probe\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e\u003cspan\u003eBasis Sensortechnologie\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eOuter diameter protection tube \/ Insert \u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eInsert: 6,0 mm\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eMax. immersion length on request\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e\u003cspan\u003eup to 1.000,0 mm (39'')\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eMaterial protection tube\/ thermowell\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003eInsert Material:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e316L (1.4404)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAlloy 600 (2.4816)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eProcess connection\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e \u003cspan\u003eThread:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eG1\/2\", G1\/4\"\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNPT1\/2\"\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eM18x1.5, M20x1.5\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCap-nut:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eG1\/2\", G3\/4\"\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCompression fitting, also spring load:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNPT1\/2\", G1\/2\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eTip shape\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e \u003cspan\u003estraight\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eOperating temperature range\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cdiv\u003e \u003cspan\u003eBasic PT100 TF:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e-50 °C …200 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(-58 °F …392 °F)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eTyp K:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emax. 1.100 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(max. 2.012 °F)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eMax. process pressure (static)\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e \u003cspan\u003edepending on the configuration\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eAccuracy\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cspan\u003eClass A acc. to IEC 60751\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eClass B acc. to IEC 60751\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eClass standard acc. to ASTM E230\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eClass 2 acc. to IEC 60584-2\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eResponse time\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\n\u003cspan\u003et90 around 17 s\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003edepending on configuration\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49.3067%;\"\u003e\n\u003ch4 class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eIntegration head transmitter\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.4106%;\"\u003e\u003cspan\u003eyes (4 … 20 mA; HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48885676671193,"sku":null,"price":720.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_hauser_Temperature_Sensor_iTHERM_ModuLine_TM101_1_8b0bc3d0-9438-49e5-be08-add0e0378d9c.png?v=1783105242","url":"https:\/\/www.aloinfousa.com.mx\/en\/products\/endresshauser-temperature-sensor-itherm-moduline-tm101","provider":"aloinfousa.com","version":"1.0","type":"link"}