{"product_id":"hpe-proliant-dl360p-gen8-server","title":"HPE ProLiant DL360p Gen8 Server","description":"\u003cdiv class=\"head-content-set-outer\"\u003e\n\u003ch2 class=\"Dell_PowerEdge_R630_Specifications\"\u003eCloud Ninjas' HPE ProLiant DL360p Gen8 Specifications\u003c\/h2\u003e\n\u003c!-- Chassis Section Order 1 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eChassis\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe HPE ProLiant DL360p Gen8 server is powerful, general-purpose server. This server is perfect for businesses of all sizes This 1U rackmount server has three chassis options to choose from: 4 Bay SFF, 8 Bay SFF, 10 Bay SFF.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e4 Bay LFF\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 4 Bay LFF chassis for the HPE ProLiant DL360p Gen8 can accept up to eight 3.5\" SAS\/SATA drives. 2.5\" hard drives and solid-state drives can be installed via a 2.5\" to 3.5\" drive converter. Drive bays for the DL360p are hot-swap, meaning that drives can be added or removed while the system is powered on. The rear of the 4 Bay LFF chassis includes two type A USB 3.0, a VGA port, a serial connector, a iLO 4 port, four 1GbE RJ45 Ethernet ports, one FLOM bay, and two hot-swap power supply bays.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e8 Bay SFF\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe DL360p Gen8's 8 Bay SFF chassis supports up to eight 2.5\" SAS\/SATA hard drives and\/or solid-state drives. Drive bays for the 8 Bay SFF chassis are hot-swap. The rear of the 10 Bay SFF chassis includes two type A USB 3.0, a VGA port, a serial connector, a iLO 4 port, four 1GbE RJ45 Ethernet ports, one FLOM bay, and two hot-swap power supply bays.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e10 Bay SFF\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe DL360p Gen8's 10 Bay SFF chassis supports up to ten 2.5\" SAS\/SATA hard drives and\/or solid-state drives. Drive bays for the 10 Bay SFF chassis are hot-swap. The rear of the 10 Bay SFF chassis includes two type A USB 3.0, a VGA port, a serial connector, a iLO 4 port, four 1GbE RJ45 Ethernet ports, one FLOM bay, and two hot-swap power supply bays.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Processing Power Section Order 2 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eProcessing Power\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe HPE ProLiant DL360p Gen8 server supports up to two 2nd Generation Intel Scalable CPUs. Total of 24 cores with a total of 12 cores per processor.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003e2nd Generation Intel Xeon Scalable\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2603v2\u003c\/td\u003e\n\u003ctd\u003eSR1AY\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e1.80 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2609v2\u003c\/td\u003e\n\u003ctd\u003eSR1AX\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e2.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2618Lv2\u003c\/td\u003e\n\u003ctd\u003eSR1B8\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e2.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2620v2\u003c\/td\u003e\n\u003ctd\u003eSR1AN\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e2.10 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2628Lv2\u003c\/td\u003e\n\u003ctd\u003eSR1AF\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e1.90 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2630v2\u003c\/td\u003e\n\u003ctd\u003eSR1AM\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2630Lv2\u003c\/td\u003e\n\u003ctd\u003eSR1AZ\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2637v2\u003c\/td\u003e\n\u003ctd\u003eSR1B7\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2640v2\u003c\/td\u003e\n\u003ctd\u003eSR19Z\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2643v2\u003c\/td\u003e\n\u003ctd\u003eSR19X\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2648Lv2\u003c\/td\u003e\n\u003ctd\u003eSR1A2\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.90 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2650v2\u003c\/td\u003e\n\u003ctd\u003eSR1A8\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2650Lv2\u003c\/td\u003e\n\u003ctd\u003eSR19Y\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.70 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2658v2\u003c\/td\u003e\n\u003ctd\u003eSR1A0\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2660v2\u003c\/td\u003e\n\u003ctd\u003eSR1AB\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.20 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2667v2\u003c\/td\u003e\n\u003ctd\u003eSR19W\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.30 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003e2nd Generation Intel Xeon Scalable\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2670v2\u003c\/td\u003e\n\u003ctd\u003eSR1A7\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2680v2\u003c\/td\u003e\n\u003ctd\u003eSR1A6\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.80 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2687Wv2\u003c\/td\u003e\n\u003ctd\u003eSR19V\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.40 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2690v2\u003c\/td\u003e\n\u003ctd\u003eSR1A5\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e3.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2695v2\u003c\/td\u003e\n\u003ctd\u003eSR1BA\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2697v2\u003c\/td\u003e\n\u003ctd\u003eSR19H\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.70 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2650Lv2\u003c\/td\u003e\n\u003ctd\u003eSR19Y\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.70 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2658v2\u003c\/td\u003e\n\u003ctd\u003eSR1A0\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2660v2\u003c\/td\u003e\n\u003ctd\u003eSR1AB\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.20 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2667v2\u003c\/td\u003e\n\u003ctd\u003eSR19W\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.30 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2670v2\u003c\/td\u003e\n\u003ctd\u003eSR1A7\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2680v2\u003c\/td\u003e\n\u003ctd\u003eSR1A6\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.80 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2687Wv2\u003c\/td\u003e\n\u003ctd\u003eSR19V\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.40 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2690v2\u003c\/td\u003e\n\u003ctd\u003eSR1A5\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e3.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2695v2\u003c\/td\u003e\n\u003ctd\u003eSR1BA\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5-2697v2\u003c\/td\u003e\n\u003ctd\u003eSR19H\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.70 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Memory Section Order 3 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eMemory\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003eDIMM slots \u0026amp; Memory Channels\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe HPE ProLiant DL360p Gen8 server is a DDR3 basd machine with 24 DIMM slots and 4 memory channels. Each channel consist of 3 DIMM slots.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSupported Memory Types\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe DL360p Gen8 accepts both ECC Registered (RDIMM), Load Reduced (LRDIMM) and ECC Unbuffered (UDIMM) memory. It is important to not mixed together memory types. For example, if you are installing LRDIMMs into your server, do not install any RDIMMs. If you are installing RDIMMs, do not install any LRDIMMs. Mixing memory types can lead to issues such as boot failure.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSupported Memory Capacities\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eCapacities of 8GB, 16GB, and 32GB. 32GB is only available with LRDIMMs, 16GB are only available with RDIMM, 8GB are only available with UDIMM. With Load Reduced and RDIMM, you can achieve an overall greater RAM capacity.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMax Configurations\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eWith ECC Registered memory, you can achieve a max of 384GB with a configuration of 24x16GB modules at 1333MHz. With Load Reduced, the max you can achieve is 768GB with a configuration of 24x32GB modules at 1066MHz. With UDIMM, 128GB can be achieved with 16x8GB modules at 1333MHz.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSupported Memory Speeds\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe HPE ProLiant DL360p Gen8 supports memory speeds of 1066MT\/s, up to 1600MT\/s. The processor you have installed will determine the max memory speed that you can use with your system. For example, if your processor supports a max memory speed off 1333MT\/s and you install a 1600MT\/s module, the module will clock down to 1333MT\/s. 1333MT\/s is the fastest possible speed for this system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eStorage\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe DL360p G10 chassis that you have will determine what form factor and number of drives you can install. With the 4 Bay LFF chassis, you can install up to four 3.5\" SAS\/SATA hard drives. With the 8 Bay SFF chassis, you can install up to eight 2.5\" SAS\/SATA hard drives. 2.5\" SAS\/SATA HDDs and\/or SSDs can be install into the 4 Bay SFF chassis via a 2.5\" to 3.5\" drive adapter. The 10 Bay SFF chassis can accept up to ten 2.5\" SAS\/SATA hard drives and\/or solid-state drives. All three chassis for the DL360p Gen8 are hot-swap, meaning the drives can be added or removed while the server is powered on.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Drives (2.5\")\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity Per Drive\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K, 10K, 15K\u003c\/td\u003e\n\u003ctd\u003e2.4TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e2TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD (SAS \u0026amp; SATA)\u003c\/td\u003e\n\u003ctd\u003e6GB\/s, 12GB\/s\u003c\/td\u003e\n\u003ctd\u003e15.36TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Drives (3.5\")\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity Per Drive\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e10TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e14TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD (SAS \u0026amp; SATA)\u003c\/td\u003e\n\u003ctd\u003e6GB\/s, 12GB\/s\u003c\/td\u003e\n\u003ctd\u003e15.36TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e \u003c!--\u003cdiv class=\"head-content-set\"\u003e\n            \u003ch3\u003e\u003cspan data-mce-fragment=\"1\"\u003eNVMe Options \u0026amp; Upgrades\u003c\/span\u003e\u003c\/h3\u003e\n            \u003cdiv class=\"head-content-set-content\"\u003e\n                \u003cp\u003e\n                    NVMe is an amazing storage technology that has a ton of benefits. It is blazing fast which is desirable\n                    in certain enterprise environments. NVMe drives are much faster compared to traditional drives.\n                    Unfortunately, there isn’t much NVMe support for the PowerEdge DL360p Gen8 server. There is only one option\n                    which is: PCIe NVMe. Neither U.2 nor M.2 will work with this server.\n                \u003c\/p\u003e\n    \n                \u003ch4\u003e\u003cstrong\u003ePCIe NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n                \u003cp\u003e\n                    The only NVMe solution for the PowerEdge DL360p Gen8 is to use a PCIe NVMe drive. Even though this will work,\n                    there are quite a few limitations. First of all, cannot use any PCIe NVMe drive of your choice. You can\n                    only use drives that have Dell firmware. A non-Dell, OEM drive will not work. Even with a PCIe NVMe\n                    drive with Dell firmware, you are still restricted. You cannot use the drive to install an operating\n                    system or to create a virtual machine. The only thing that this NVMe solution can be used for is\n                    additional storage. One thing to check is to make sure that the slot disablement setting in the BIOS is\n                    enabled. If it is disabled, the drive will not be recognized by the server.\n                \u003c\/p\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n        --\u003e \u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003ePower Supplies\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003ePower Supplies Overview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\nThe power supply options for the DL360p Gen8 are: 460W Platinum, 750W Platinum, and 1200W Platinum. Each power supply option is hot-swap, which means that PSUs can be added or removed from the server while it is running, as long as one power supply remains plugged in. There two power supply bays on the rear of each chassis option. If you install two power supplies, the wattages and voltages of the units must be matching. All power supply options for the DL360p Gen8 are great options, but the one that is best for you depends on your application. For low end applications, 460W power supplies are a grea option. For higher end applications, 750W or 1200W will work just fine.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 5 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eRAID Options\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe HPE ProLiant DL360p Gen8 has support for Embedded and PCIe RAID controllers. Embedded RAID controllers have a dedicated spot of the motherboard that the card is installed.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRAID Options\u003c\/th\u003e\n\u003cth\u003eRAID Levels\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003cth\u003eDrive Speeds\u003c\/th\u003e\n\u003cth\u003ePCIe Generation\u003c\/th\u003e\n\u003cth\u003eRAID Hardware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart Array S100i Software\u003c\/td\u003e\n\u003ctd\u003e0, 1, 5, 10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart Array P420i\u003c\/td\u003e\n\u003ctd\u003e0, 1, 1+0 , 5, 5+0, 6, 6+0\u003c\/td\u003e\n\u003ctd\u003e1GB\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart Array P420i\u003c\/td\u003e\n\u003ctd\u003e0, 1, 1+0 , 5, 5+0, 6, 6+0\u003c\/td\u003e\n\u003ctd\u003e2GB\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Network Interface Card Options Section Order 6 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eNetwork Interface Card Options\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe HPE DL360p Gen8 server has 2 2GbE port integrated into the motherboard. There is also a dedidicated FlexibleLom (FLOM) slot in the rear of the system. This FLOM slot allow you to install cards with up to two ports. If you want additional networking capabilities in addition to the built in network ports and an FLOM card, you can also install PCIe network cards. FLOM and PCIe network cards are available with a variety of different speeds and port types. There are cards with port interfaces of RJ45, SFP, SFP+, SFP28, QSFP, and QSFP28. There are also speed options of 1GbE, 10GbE, 25GbE, 40GbE, and 100GbE. The number of ports, network speeds, and port interfaces that are best for you are entirely based on you applications.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eFlexibleLOM (FLOM) Network Cards\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Ethernet 1Gb 4-port 331FLR FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Ethernet 10Gb 2-port 530FLR-SFP+ FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPE Ethernet 561FLR-T Dual Port 2 x 10GbE RJ45 Network Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP FlexFabric 10Gb 2-port 554FLR-SFP+ FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Ethernet 1Gb 4-port 366FLR FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Ethernet 10Gb 2-port 560FLR-SFP+ FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP FlexFabric 10Gb 2-port 526FLR-SFP+ FIO Adapterr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPE FlexFabric 536FLR-T Quad Port 4 x 10GbE RJ45 Network Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eFlexibleLOM (FLOM) Network Cards\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPE FlexFabric 534FLR-SFP+ Dual Port 2 x 10GbE SFP+ Network Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Ethernet 10Gb 2-port 561FLR-T FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP FlexFabric 10Gb 2-port 533FLR-T FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Ethernet 10Gb 2-port 570FLR-SFP+ FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Ethernet 10Gb 2-port 571FLR-SFP+ FIO Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP InfiniBand FDR 2-port 545QSFP Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Infiniband FDR\/Ethernet 10Gb\/40Gb 2-port 544FLR-QSFP Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP Infiniband QDR\/Ethernet 10Gb 2-port 544FLR-QSFP Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSystems Management Solutions\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eFor server management, the HPE ProLiant DL360p Gen8 server utilizes Integrated Lights-Out 4 (iLO 4). The iLO can be accessed via the integrated iLO port on the rear of the DL360p Gen8. iLO features include: Active Health System Logs, Agentless Management, Deployment and Provisioning, Embedded Remoted Support, iLO Federation Management, Integrated Management Log, Integrated Remote Console, Power Consumption and Power Settings, Power Management, Server Health Monitoring, User Access, and Virtual Media. The iLO has two license types: standard and advanced. A standard license is more limited than the advanced license. The main difference between the two licenses is that an advanced license allows you to use remote console and media functions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 8 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSupported Operating Systems:\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe HPE ProLiant DL360p Gen8 Server supports a wide variety of operating systems which ranges from different distributions of Linux, VMware, and Windows Server. The operating systems include, but are not limited to:\u003c\/p\u003e\n\u003cul class=\"custom_dots\" style=\"columns: 4; -webkit-columns: 4; -moz-columns: 4;\"\u003e\n\u003cli\u003e⦿ Red Hat Enterprise Linux 6.9 and 7.3\u003c\/li\u003e\n\u003cli\u003e⦿ SUSE Linux Enterprise Server 11 SP4 and 12 SP2\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.0 U3\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.5 U1\u003c\/li\u003e\n\u003cli\u003e⦿ ClearOS\u003c\/li\u003e\n\u003cli\u003e⦿ CentOS\u003c\/li\u003e\n\u003cli\u003e⦿ Windows Server 2012 R2\u003c\/li\u003e\n\u003cli\u003e⦿ Windows Server 2016\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cloud Ninjas","offers":[{"title":"Default Title","offer_id":48026216661209,"sku":"HP-DL360-G8-10B-NVMe-SFF","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/DL360p-Chassis-_1.jpg?v=1772023607","url":"https:\/\/www.aloinfousa.com.mx\/en\/products\/hpe-proliant-dl360p-gen8-server","provider":"aloinfousa.com","version":"1.0","type":"link"}