{"product_id":"juniper-ptx10003-160c-dc-router-zpntb","title":"Juniper PTX10003-160C-DC Router","description":"\u003cdiv class=\"short-hide\" data-mce-fragment=\"1\"\u003e[shortdesc]\n\u003cul data-mce-fragment=\"1\"\u003e\n\n\u003cli data-mce-fragment=\"1\"\u003ePTX10003-160C base system with 160 100GE ports or 32 400GE ports, 4 3000W DC power supplies, and 5 fan trays, with standard tier right-to-use license\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n[properties]\u003cmeta charset=\"utf-8\"\u003e\n\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"222\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"364\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Properties\"}' data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Juniper PTX10003-160C-DC\"}' data-mce-fragment=\"1\"\u003eJuniper PTX10003-160C-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Description\"}' data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX10003-160C base system with 160 100GbE ports or 32 400GbE ports, 4 3000W DC power supplies, 4 power cables, and 5 fan trays, with standard tier right-to-use license\"}' data-mce-fragment=\"1\"\u003ePTX10003-160C base system with 160 100GbE ports or 32 400GbE ports, 4 3000W DC power supplies, 4 power cables, and 5 fan trays, with standard tier right-to-use license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Product Family\"}' data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX10003 Series\"}' data-mce-fragment=\"1\"\u003ePTX10003 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Product Type\"}' data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Router\"}' data-mce-fragment=\"1\"\u003eRouter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" data-sheets-value='{\"1\":2,\"2\":\"Port Densities\"}' data-mce-fragment=\"1\"\u003ePort Densities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max. 10GbE\"}' data-mce-fragment=\"1\"\u003eMax. 10GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":320}' data-mce-fragment=\"1\"\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max. 40GbE\"}' data-mce-fragment=\"1\"\u003eMax. 40GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":80}' data-mce-fragment=\"1\"\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max. 100GbE \"}' data-mce-fragment=\"1\"\u003eMax. 100GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":160}' data-mce-fragment=\"1\"\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max 200GbE\"}' data-mce-fragment=\"1\"\u003eMax 200GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":64}' data-mce-fragment=\"1\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max 400GbE\"}' data-mce-fragment=\"1\"\u003eMax 400GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":32}' data-mce-fragment=\"1\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Dimension (WxHxD)\"}' data-mce-fragment=\"1\"\u003eDimension (WxHxD)\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"17.4 x 5.25 x 31 in (44.2 x 13.3 x 78.7 cm)\"}' data-mce-fragment=\"1\"\u003e17.4 x 5.25 x 31 in (44.2 x 13.3 x 78.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Weight (lb\/kg) fully configured\"}' data-mce-fragment=\"1\"\u003eWeight (lb\/kg) fully configured\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"110 lb (50 kg)\"}' data-mce-fragment=\"1\"\u003e110 lb (50 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Rack units\"}' data-mce-fragment=\"1\"\u003eRack units\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"3 U\"}' data-mce-fragment=\"1\"\u003e3 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Maximum power draw\"}' data-mce-fragment=\"1\"\u003eMaximum power draw\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"~4000 W (AC.DC), 13640 BTU\/hr\"}' data-mce-fragment=\"1\"\u003e~4000 W (AC.DC), 13640 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Typical power draw\"}' data-mce-fragment=\"1\"\u003eTypical power draw\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"~3100W (AC,DC), 10571 BTU\/hr\"}' data-mce-fragment=\"1\"\u003e~3100W (AC,DC), 10571 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Power supply \"}' data-mce-fragment=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"4x3000 watts (AC\/DC)\"}' data-mce-fragment=\"1\"\u003e4x3000 watts (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Cooling (front-to-back fan)\"}' data-mce-fragment=\"1\"\u003eCooling (front-to-back fan)\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"5 hot-swappable redundant fans \"}' data-mce-fragment=\"1\"\u003e5 hot-swappable redundant fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/properties][specifications]\u003cmeta charset=\"utf-8\"\u003e\n\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"383\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"382\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Specifications\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX10003-160C-DC\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003ePTX10003-160C-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"CPU\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eCPU\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Intel Broadwell CPU with 12 Cores \"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eIntel Broadwell CPU with 12 Cores\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"RAM\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eRAM\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"64 Gb SDRAM \"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e64 Gb SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SSD\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSSD\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"200 GBx2\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e200 GBx2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"System throughput\"}' data-mce-fragment=\"1\"\u003eSystem throughput\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16 Tbps\"}' data-mce-fragment=\"1\"\u003e16 Tbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Forwarding capacity\"}' data-mce-fragment=\"1\"\u003eForwarding capacity\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Up to 10.6 Bpps\"}' data-mce-fragment=\"1\"\u003eUp to 10.6 Bpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Packet buffer\"}' data-mce-fragment=\"1\"\u003ePacket buffer\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"128 Gb\"}' data-mce-fragment=\"1\"\u003e128 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Latency\"}' data-mce-fragment=\"1\"\u003eLatency\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"2.5 µs within PFE, 5 us between PFEs\"}' data-mce-fragment=\"1\"\u003e2.5 µs within PFE, 5 us between PFEs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Power Efficiency (watts\/Gbps)\"}' data-mce-fragment=\"1\"\u003ePower Efficiency (watts\/Gbps)\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"0.2\"}' data-mce-fragment=\"1\"\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Management and Precision Time Protocol (PTP) interfaces\"}' data-mce-fragment=\"1\"\u003eManagement and Precision Time Protocol (PTP) interfaces\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"1 small form-factor pluggable transceiver (SFP\/SFP+) port or\\nPrecision Time Protocol (PTP) Grandmaster\\nFiber (SFP) or 10\/100\/1000BASE-T (RJ-45) Ethernet management port\\nSMB in, SMB out, 10 MHz in, 10 MHz out\\nOne console port\\nUSB 2.0 storage interface\"}' data-mce-fragment=\"1\"\u003e1 small form-factor pluggable transceiver (SFP\/SFP+) port or\u003cbr data-mce-fragment=\"1\"\u003ePrecision Time Protocol (PTP) Grandmaster\u003cbr data-mce-fragment=\"1\"\u003eFiber (SFP) or 10\/100\/1000BASE-T (RJ-45) Ethernet management port\u003cbr data-mce-fragment=\"1\"\u003eSMB in, SMB out, 10 MHz in, 10 MHz out\u003cbr data-mce-fragment=\"1\"\u003eOne console port\u003cbr data-mce-fragment=\"1\"\u003eUSB 2.0 storage interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Total packet buffer\"}' data-mce-fragment=\"1\"\u003eTotal packet buffer\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"24 GB\"}' data-mce-fragment=\"1\"\u003e24 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Software Features\"}' data-mce-fragment=\"1\"\u003eSoftware Features\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"MPLS-TE\\nMPLS LSR\\nFirewall filters ACL\\nSPRINGv4\\nDDoS control plane\\nJFlow\/SFlow\\nBGP FlowSpec, EPE, URPF, L3VPN\\nIntegrated routing and bridging (IRB)\\nTelemetry, NETCONF\/YANG\\nZero Touch Provisioning (ZTP)\\nPCEP, BGP-LS\\nFast restoration\\nOperation, Administration, and Maintenance (OAM)\"}' data-mce-fragment=\"1\"\u003eMPLS-TE\u003cbr data-mce-fragment=\"1\"\u003eMPLS LSR\u003cbr data-mce-fragment=\"1\"\u003eFirewall filters ACL\u003cbr data-mce-fragment=\"1\"\u003eSPRINGv4\u003cbr data-mce-fragment=\"1\"\u003eDDoS control plane\u003cbr data-mce-fragment=\"1\"\u003eJFlow\/SFlow\u003cbr data-mce-fragment=\"1\"\u003eBGP FlowSpec, EPE, URPF, L3VPN\u003cbr data-mce-fragment=\"1\"\u003eIntegrated routing and bridging (IRB)\u003cbr data-mce-fragment=\"1\"\u003eTelemetry, NETCONF\/YANG\u003cbr data-mce-fragment=\"1\"\u003eZero Touch Provisioning (ZTP)\u003cbr data-mce-fragment=\"1\"\u003ePCEP, BGP-LS\u003cbr data-mce-fragment=\"1\"\u003eFast restoration\u003cbr data-mce-fragment=\"1\"\u003eOperation, Administration, and Maintenance (OAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Operating temperature\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"32° to 115° F (0° to 46° C) at sea level\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e32° to 115° F (0° to 46° C) at sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Storage temperature\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"-40° to 158° F (-40° to 70° C)\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Operating altitude\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Up to 10,000 ft. (3,048 m) \"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eUp to 10,000 ft. (3,048 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Relative humidity operating\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"5 to 90% (noncondensing)\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e5 to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Relative humidity nonoperating\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eRelative humidity nonoperating\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"5 to 95% (noncondensing)\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Seismic\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSeismic\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Designed to meet GR-63, Zone 4 earthquake requirements\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eDesigned to meet GR-63, Zone 4 earthquake requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Safety\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSafety\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"CAN\/CSA-C22.2 No. 60950-1 Information Technology\\nEquipmentSafety\\nUL 60950-1 Information Technology EquipmentSafety\\nEN 60950-1 Information Technology EquipmentSafety\\nIEC 60950-1 Information Technology EquipmentSafety (all\\ncountry deviations)\\nEN 60825-1 Safety of Laser ProductsPart 1: Equipment\\nClassification\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eCAN\/CSA-C22.2 No. 60950-1 Information Technology\u003cbr data-mce-fragment=\"1\"\u003eEquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003eUL 60950-1 Information Technology EquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003eEN 60950-1 Information Technology EquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003eIEC 60950-1 Information Technology EquipmentSafety (all\u003cbr data-mce-fragment=\"1\"\u003ecountry deviations)\u003cbr data-mce-fragment=\"1\"\u003eEN 60825-1 Safety of Laser ProductsPart 1: Equipment\u003cbr data-mce-fragment=\"1\"\u003eClassification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"EMC\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eEMC\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"47CFR Part 15, (FCC) Class A\\nICES-003 Class A\\nEN 55022 Class A\\nCISPR 22 Class A\\nEN 55024\\nCISPR 24\\nEN 300 386\\nVCCI Class A\\nAS\/NZA CISPR22 Class A\\nKN22 Class A\\nCNS 13438 Class A\\nEN 61000-3-2\\nEN 61000-3-3\\nETSI\\nETSI EN 300 019: Environmental Conditions \u0026amp; Environmental\\nTests for Telecommunications Equipment\\nETSI EN 300 019-2-1 (2000)Storage\\nETSI EN 300 019-2-2 (1999)Transportation\\nETSI EN 300 019-2-3 (2003)Stationary Use at Weatherprotected Locations\\nETS 300753 (1997)Acoustic noise emitted by\\ntelecommunications equipment\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e47CFR Part 15, (FCC) Class A\u003cbr data-mce-fragment=\"1\"\u003eICES-003 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022 Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eCISPR 24\u003cbr data-mce-fragment=\"1\"\u003eEN 300 386\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZA CISPR22 Class A\u003cbr data-mce-fragment=\"1\"\u003eKN22 Class A\u003cbr data-mce-fragment=\"1\"\u003eCNS 13438 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-2\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-3\u003cbr data-mce-fragment=\"1\"\u003eETSI\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019: Environmental Conditions \u0026amp; Environmental\u003cbr data-mce-fragment=\"1\"\u003eTests for Telecommunications Equipment\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-1 (2000)Storage\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-2 (1999)Transportation\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-3 (2003)Stationary Use at Weatherprotected Locations\u003cbr data-mce-fragment=\"1\"\u003eETS 300753 (1997)Acoustic noise emitted by\u003cbr data-mce-fragment=\"1\"\u003etelecommunications equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/specifications][accesories]\u003cmeta charset=\"utf-8\"\u003e\n\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"149\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"271\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" data-sheets-value='{\"1\":2,\"2\":\"Accessories and licenses\"}' data-mce-fragment=\"1\"\u003eAccessories and licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-A1-P \"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-A1-P\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Advanced1 tier right-to-use license, perpetual, without SW support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Advanced1 tier right-to-use license, perpetual, without SW support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-A2-P \"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-A2-P\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Advanced2 tier right-to-use license, perpetual, without SW support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Advanced2 tier right-to-use license, perpetual, without SW support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-P1-P \"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-P1-P\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Premium1 tier right-to-use license, perpetual, without SW support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Premium1 tier right-to-use license, perpetual, without SW support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-P2-P\"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-P2-P\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Premium2 tier right-to-use license, perpetual, without SW support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Premium2 tier right-to-use license, perpetual, without SW support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-A1-5 \"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-A1-5\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Advanced1 tier right-to-use license, 5-year term, with SW support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Advanced1 tier right-to-use license, 5-year term, with SW support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-A2-5\"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-A2-5\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Advanced2 tier right-to-use license, 5-year term, with software support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Advanced2 tier right-to-use license, 5-year term, with software support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-P1-5 \"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-P1-5\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Premium1 tier right-to-use license, 5-year term, with software support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Premium1 tier right-to-use license, 5-year term, with software support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-P2-5\"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-P2-5\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Premium2 tier right-to-use license, 5-year term, with software support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Premium2 tier right-to-use license, 5-year term, with software support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-A1-3\"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-A1-3\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Advanced1 tier right-to-use license, 3-year term, with SW support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Advanced1 tier right-to-use license, 3-year term, with SW support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-A2-3\"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-A2-3\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Advanced2 tier right-to-use license, 3-year term, with software support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Advanced2 tier right-to-use license, 3-year term, with software support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-P1-3\"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-P1-3\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Premium1 tier right-to-use license, 3-year term, with software support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Premium1 tier right-to-use license, 3-year term, with software support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K3-16T-P2-3\"}' data-mce-fragment=\"1\"\u003eS-PTX10K3-16T-P2-3\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"16T PTX10003 Premium2 tier right-to-use license, 3-year term, with software support\"}' data-mce-fragment=\"1\"\u003e16T PTX10003 Premium2 tier right-to-use license, 3-year term, with software support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"JNP10003-160C-CHAS\"}' data-mce-fragment=\"1\"\u003eJNP10003-160C-CHAS\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"JNP10003-160C spare chassis with 160 100GbE ports or 32 400GbE ports\"}' data-mce-fragment=\"1\"\u003eJNP10003-160C spare chassis with 160 100GbE ports or 32 400GbE ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"JNP10003-FAN\"}' data-mce-fragment=\"1\"\u003eJNP10003-FAN\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Fan tray for 3RU 8T and 16T fixed platforms\"}' data-mce-fragment=\"1\"\u003eFan tray for 3RU 8T and 16T fixed platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"JNP-3000W-DC-AFO\"}' data-mce-fragment=\"1\"\u003eJNP-3000W-DC-AFO\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"AC power supply for JNP10003-160C and NP10003-80C fixed platforms\"}' data-mce-fragment=\"1\"\u003eAC power supply for JNP10003-160C and NP10003-80C fixed platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" data-sheets-value='{\"1\":2,\"2\":\"Pay-as-you-grow License\"}' data-mce-fragment=\"1\"\u003ePay-as-you-grow License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K-400G-P1-3\"}' data-mce-fragment=\"1\"\u003eS-PTX10K-400G-P1-3\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SW, PTX10K, 400G, Premium 1, with SW support, Flex Capacity License, JAL required, 3 YEAR\"}' data-mce-fragment=\"1\"\u003eSW, PTX10K, 400G, Premium 1, with SW support, Flex Capacity License, JAL required, 3 YEAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K-400G-P1-5\"}' data-mce-fragment=\"1\"\u003eS-PTX10K-400G-P1-5\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SW, PTX10K, 400G, Premium 1, with SW support, Flex Capacity License, JAL required, 5 YEAR\"}' data-mce-fragment=\"1\"\u003eSW, PTX10K, 400G, Premium 1, with SW support, Flex Capacity License, JAL required, 5 YEAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K-400G-P1-P\"}' data-mce-fragment=\"1\"\u003eS-PTX10K-400G-P1-P\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SW, PTX10K, 400G, Pre1, without SW support, Perpetual\"}' data-mce-fragment=\"1\"\u003eSW, PTX10K, 400G, Pre1, without SW support, Perpetual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K-400G-P2-3\"}' data-mce-fragment=\"1\"\u003eS-PTX10K-400G-P2-3\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SW, PTX10K, 400G, Premium 2, with SW support, Flex Capacity License, JAL required, 3 YEAR\"}' data-mce-fragment=\"1\"\u003eSW, PTX10K, 400G, Premium 2, with SW support, Flex Capacity License, JAL required, 3 YEAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K-400G-P2-5 \"}' data-mce-fragment=\"1\"\u003eS-PTX10K-400G-P2-5\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SW, PTX10K, 400G, Premium 2, with SW support, Flex Capacity License, JAL required, 5 YEAR\"}' data-mce-fragment=\"1\"\u003eSW, PTX10K, 400G, Premium 2, with SW support, Flex Capacity License, JAL required, 5 YEAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX10K-400G-P2-P \"}' data-mce-fragment=\"1\"\u003eS-PTX10K-400G-P2-P\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SW, PTX10K, 400G, Pre2, without SW support, Perpetual\"}' data-mce-fragment=\"1\"\u003eSW, PTX10K, 400G, Pre2, without SW support, Perpetual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/accesories]\n\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe scalable PTX10003 Packet Transport Router delivers critical core routing functions on demand while providing high-density 10GbE, 40GbE, 100GbE, 200GbE, and 400GbE interfaces for distributed core networks and network applications. The router's compact form factor and power efficiency meets the demands of Internet service providers, cloud providers, cable multiple service operators (MSOs), and high-volume content providers. The PTX10003 offers secure transit, peering, and full IP\/MPLS and SPRING applications in the data center edge and content delivery network (CDN) core.\u003c\/span\u003e\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013191938265,"sku":"PTX10003-160C-DC-NEW","price":391387.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ptx10003_2d05f44a-dab2-4f16-bf98-efb8b0f6ab73.jpg?v=1771851717","url":"https:\/\/www.aloinfousa.com.mx\/he\/products\/juniper-ptx10003-160c-dc-router-zpntb","provider":"aloinfousa.com","version":"1.0","type":"link"}