{"product_id":"cisco-ir1821-k9-router-iut7b","title":"Cisco IR1821-K9 Router","description":"\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"1067\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 187.164px;\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 362.336px;\"\u003eCisco IR1821-K9 Router\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 187.164px;\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 362.336px;\"\u003eThe Cisco IR1821-K9 Router is a versatile networking solution designed for industrial environments. With its compact design and advanced features, it delivers secure and reliable connectivity for critical applications in demanding settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 187.164px;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 362.336px;\"\u003eCisco Catalyst IR1800 Rugged Series Routers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 187.164px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 362.336px;\"\u003eRouter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 187.164px;\"\u003eKey Features\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 362.336px;\"\u003e• Memory: 4 GB\u003cbr data-mce-fragment=\"1\"\u003e• Pluggable slots (cellular: 1\u003cbr data-mce-fragment=\"1\"\u003e• Wide pluggable slot (Wi-Fi: 1\u003cbr data-mce-fragment=\"1\"\u003e• CAN bus: ✓ \u003cbr data-mce-fragment=\"1\"\u003e• Ignition power management: ✓ \u003cbr data-mce-fragment=\"1\"\u003e• Gigabit Ethernet (GE LAN (x4: ✓ \u003cbr data-mce-fragment=\"1\"\u003e• Combo RJ-45\/SFP GE WAN port (L3 (x1: ✓ \u003cbr data-mce-fragment=\"1\"\u003e• Micro USB console: ✓ \u003cbr data-mce-fragment=\"1\"\u003e• Power over Ethernet (PoE\/PoE: -\u003cbr data-mce-fragment=\"1\"\u003e• SSD: -\u003cbr data-mce-fragment=\"1\"\u003e• Automotive dead reckoning GNSS slot: - \u003cbr data-mce-fragment=\"1\"\u003e• Digital I\/O (x4: - \u003cbr data-mce-fragment=\"1\"\u003e• Serial interface: RS-232 (1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties] [specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" style=\"height: 2570px;\" width=\"628\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; height: 19px; width: 555.5px;\" colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; height: 19px; width: 555.5px;\" colspan=\"2\"\u003eMemory specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 266.242px;\"\u003eDefault and maximum DRAM \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 283.258px;\"\u003e4 GB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 39px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 266.242px;\"\u003eDefault and maximum flash memory\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 283.258px;\"\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 78px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 78px; width: 266.242px;\"\u003eBackup flash storage\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 78px; width: 283.258px;\"\u003e● Provides an added layer of protection from improper shutdown cycles, thus preventing any kind of\u003cbr data-mce-fragment=\"1\"\u003ememory corruptions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; height: 19px; width: 555.5px;\" colspan=\"2\"\u003ePhysical specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 58px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 58px; width: 266.242px;\"\u003ePhysical dimensions\u003cbr data-mce-fragment=\"1\"\u003e(H x W x D \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 58px; width: 283.258px;\"\u003e● 2.20 x 11.04 x 8.06 in. (55.9 x 280.4 x 204.7 mm \u003cbr data-mce-fragment=\"1\"\u003e● 2.20 x 11.04 x 9.73 in. (55.9 x 280.4 x 247.0 mm with additional IP54-KIT (IR1800-IP54-KIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 39px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 266.242px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 283.258px;\"\u003e● 2.4 kg (5.3 lb (without any modules\u003cbr data-mce-fragment=\"1\"\u003e● 3.1 kg (6.8 lb (fully configured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 58px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 58px; width: 266.242px;\"\u003eIP rating \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 58px; width: 283.258px;\"\u003e● IP40 rated\u003cbr data-mce-fragment=\"1\"\u003e● IP54 rated with additional IP54-KIT (IR1800-IP54-KIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 39px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 266.242px;\"\u003eMounting options \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 283.258px;\"\u003e● DIN rail\u003cbr data-mce-fragment=\"1\"\u003e● Panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; height: 19px; width: 555.5px;\" colspan=\"2\"\u003ePower specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 78px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 78px; width: 266.242px;\"\u003ePower input \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 78px; width: 283.258px;\"\u003e● Nominal voltage: +12V and +24V\u003cbr data-mce-fragment=\"1\"\u003e● Minimum and maximum input voltage: 9V - 36V\u003cbr data-mce-fragment=\"1\"\u003e● Maximum and Minimum input current: 7.56A - 1.99A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 58px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 58px; width: 266.242px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 58px; width: 283.258px;\"\u003e● At idle: 16W (at 12V, 17W (at 24V\u003cbr data-mce-fragment=\"1\"\u003e● Typical: 22W (at 12V, 23W (at 24V\u003cbr data-mce-fragment=\"1\"\u003e● Maximum: 27W (without PoE, 71W (with PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; height: 19px; width: 555.5px;\" colspan=\"2\"\u003eInterfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 156px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 156px; width: 266.242px;\"\u003e WAN interfaces \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 156px; width: 283.258px;\"\u003e● Pluggable Interface Module slots\u003cbr data-mce-fragment=\"1\"\u003e◦ IR1821: 1x for Cisco Cellular Pluggable Interface Modules\u003cbr data-mce-fragment=\"1\"\u003e● Wide interface pluggable module slots-\u003cbr data-mce-fragment=\"1\"\u003e◦ 1x on all IR1800 models for Cisco Wi-Fi 6 Wide Interface Pluggable Module\u003cbr data-mce-fragment=\"1\"\u003e● Combo 10\/100\/1000 Mbps Ethernet port (RJ-45 and SFP (1x on all IR1800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 266.242px;\"\u003eLAN interfaces \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 283.258px;\"\u003e● 4x 10\/100\/1000 Mbps RJ-45 Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 266.242px;\"\u003eAsynchronous serial interfaces\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 283.258px;\"\u003e● IR1821: 1x RS-232 DTE port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 266.242px;\"\u003eConsole\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 283.258px;\"\u003e● 1 micro-USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 39px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 266.242px;\"\u003ePower input\/CAN bus combo\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 283.258px;\"\u003e● 4-pin Molex Mini-Fit port for power and CAN bus (see accessories for more details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 39px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 266.242px;\"\u003eIgnition power management\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 39px; width: 283.258px;\"\u003e● All IR1800 models have automatic ignition power management capability for Ignition Sense.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 266.242px;\"\u003eUSB port\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 283.258px;\"\u003e● 1x USB 2.0 Type A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 176px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 176px; width: 266.242px;\"\u003eStatus LEDs\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 176px; width: 283.258px;\"\u003e● Top surface-\u003cbr data-mce-fragment=\"1\"\u003e◦ 1x system status LED\u003cbr data-mce-fragment=\"1\"\u003e● Front surface\u003cbr data-mce-fragment=\"1\"\u003e◦ 1x ignition power management LED\u003cbr data-mce-fragment=\"1\"\u003e◦ 1x system status LED\u003cbr data-mce-fragment=\"1\"\u003e◦ 4x Gigabit Ethernet LEDs\u003cbr data-mce-fragment=\"1\"\u003e◦ 2x Combo Gigabit Ethernet-SFP LEDs\u003cbr data-mce-fragment=\"1\"\u003e● Cellular and Wi-Fi modules have power and status LEDs on the modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; height: 19px; width: 555.5px;\" colspan=\"2\"\u003eEnvironmental specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 215px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 215px; width: 266.242px;\"\u003eEnvironmental operating temperature range\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 215px; width: 283.258px;\"\u003e● –40° to 140°F (–40° to 60°C in a sealed NEMA cabinet with no airflow\u003cbr data-mce-fragment=\"1\"\u003e● –40° to 158°F (–40° to 70°C in a vented cabinet with 40 linear feet per minute (LFM of air\u003cbr data-mce-fragment=\"1\"\u003e● –40° to 167°F (–40° to 75°C in a forced air enclosure with 200 LFM of air\u003cbr data-mce-fragment=\"1\"\u003e● Type tested at 85°C for 16 hours\u003cbr data-mce-fragment=\"1\"\u003e● Refer to the IR1800 Hardware Installation Guide (HIG for the operating temperature range for\u003cbr data-mce-fragment=\"1\"\u003epluggable cellular modules and wide pluggable Wi-Fi modules \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 266.242px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 19px; width: 283.258px;\"\u003e● Maximum altitude: 13.800 ft per IEC 68-2-41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 19px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; height: 19px; width: 555.5px;\" colspan=\"2\"\u003eStandards and industry specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 137px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 137px; width: 266.242px;\"\u003eMechanical\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 137px; width: 283.258px;\"\u003e● SAE J1455 (Automobile Standard\u003cbr data-mce-fragment=\"1\"\u003e● Temperature cycle stress test\u003cbr data-mce-fragment=\"1\"\u003e● Active 10-day temperature and humidity test\u003cbr data-mce-fragment=\"1\"\u003e● MIL-STD 810G (Military Standard\u003cbr data-mce-fragment=\"1\"\u003e● Method 514.6, Category 4 – Random Vibration\u003cbr data-mce-fragment=\"1\"\u003e● Method 516.6, Procedure V – Crash Hazard Shock\u003cbr data-mce-fragment=\"1\"\u003e● Method 516.6, Procedure I – Functional Shock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 78px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 78px; width: 266.242px;\"\u003eAutomotive\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 78px; width: 283.258px;\"\u003e● UNECE R10\u003cbr data-mce-fragment=\"1\"\u003e● CISPR25\u003cbr data-mce-fragment=\"1\"\u003e● ISO 7637 – 2\u003cbr data-mce-fragment=\"1\"\u003e● ISO 11452 – 2\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 215px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 215px; width: 266.242px;\"\u003eHazardous locations and ITE safety\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 215px; width: 283.258px;\"\u003e● UL 121201 (Class l, Div. 2, groups A-D\u003cbr data-mce-fragment=\"1\"\u003e● CSA 213 (Class l, Div. 2, groups A-D\u003cbr data-mce-fragment=\"1\"\u003e● UL\/CSA 60079-0, -15 (Class l, Zone 2, Gc\/IIC\u003cbr data-mce-fragment=\"1\"\u003e● IEC 60079-0, 7 -15 IECEx test report (Class l, Zone 2, Gc\/IIC\u003cbr data-mce-fragment=\"1\"\u003e● EN 60079-0, 7, 15 ATEX certificate (Class l, Zone 2, Gc\/IIC\u003cbr data-mce-fragment=\"1\"\u003e● UL\/CSA 60950-1\u003cbr data-mce-fragment=\"1\"\u003e● UL\/CSA 62368-1\u003cbr data-mce-fragment=\"1\"\u003e● IEC\/EN 60950-1\u003cbr data-mce-fragment=\"1\"\u003e● IEC\/EN 62368-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 352px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 352px; width: 266.242px;\"\u003eEMC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 352px; width: 283.258px;\"\u003e● FCC part 47 CFR Part 15 Subpart B Class A\u003cbr data-mce-fragment=\"1\"\u003e● EN 5032\/CISPR 32 Class A\u003cbr data-mce-fragment=\"1\"\u003e● VCCI Class A, AS\/NZS CISPR 32 Class A\u003cbr data-mce-fragment=\"1\"\u003e● CISPR 11 Class A, ICES 003 Class A\u003cbr data-mce-fragment=\"1\"\u003e● CNS 13438 Class A, KN 32 Class A\u003cbr data-mce-fragment=\"1\"\u003e● EN 300 386\u003cbr data-mce-fragment=\"1\"\u003e● CISPR35\/EN 55035\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-2 (ESD - Air\/Contact Charge\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-3 (Radiated Immunity\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-4 (Electro Fast Transients Burst\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-5 (Surge\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-6 (Conducted Immunity\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-8 (Power Frequency Magnetic Field Immunity\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-9 (Pulse Magnetic Field Immunity\u003cbr data-mce-fragment=\"1\"\u003e● EN\/IEC61000-4-11 (Voltage Disturbance Immunity \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 195px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 195px; width: 266.242px;\"\u003eRadio (cellular \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 195px; width: 283.258px;\"\u003e● FCC 47 CFR Part 22,24,27\u003cbr data-mce-fragment=\"1\"\u003e● FCC 47 CFR Part 2 MPE\u003cbr data-mce-fragment=\"1\"\u003e● RSS 102, 132, 133\u003cbr data-mce-fragment=\"1\"\u003e● AS\/NZ: ACMA EMR, AS\/CA S042.1, 4\u003cbr data-mce-fragment=\"1\"\u003e● Japan MIC Article 2, 9\u003cbr data-mce-fragment=\"1\"\u003e● EN 301 489-1,19,52\u003cbr data-mce-fragment=\"1\"\u003e● EN 301 908-1,2,13\u003cbr data-mce-fragment=\"1\"\u003e● EN 301 511\u003cbr data-mce-fragment=\"1\"\u003e● EN 303 413\u003cbr data-mce-fragment=\"1\"\u003e● EN 62311 MPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 274px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 274px; width: 266.242px;\"\u003eRadio (Wi-Fi \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 274px; width: 283.258px;\"\u003e● FCC CFR Part 15.247, 15.407\u003cbr data-mce-fragment=\"1\"\u003e● RSS 247 Issues 5\u003cbr data-mce-fragment=\"1\"\u003e● EN 300 328, EN 301 893\u003cbr data-mce-fragment=\"1\"\u003e● AS\/NZ 4268:2018\u003cbr data-mce-fragment=\"1\"\u003e● 2018.7 (MSIT notice 2018-38, 2017.9 (MSIT notice # 2017-10\u003cbr data-mce-fragment=\"1\"\u003e● NOTACNCANEH N° 14\/2013, NOTACNCANEH N° 14\/2013\u003cbr data-mce-fragment=\"1\"\u003e● Act n° 14448 (2017-12-04\u003cbr data-mce-fragment=\"1\"\u003e● MIIT R-2002-353, MIIT R-2002-277, MIIT R-2012-620\u003cbr data-mce-fragment=\"1\"\u003e● LP0002;2018\u003cbr data-mce-fragment=\"1\"\u003e● Résolution 1985\/2017 + Res. 1517\/2018 + Res. 855\/2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications] [accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"655\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" style=\"text-align: center; width: 555.5px;\"\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eCompatible antennas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eANT-7-5G4WL2G1-O \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e7-in-1 outdoor vehicle mount antenna- 4G LTE SMA x4, Wi-Fi dual band RP-SMA x2, GNSS SMA x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eLTE-ANTM2-SMA-D \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e4G LTE dipole antenna 698-960, 1448-1511, 1710-2690 MHz, SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003e5G-ANTM-SMA-D\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e5G Sub-6 \u0026amp; LTE Advanced Pro capable dipole antenna, SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eW-ANTM2050D-RPSMA\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eWi-Fi dual band swivel dipole antenna, RP-SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eANT-4G-OMNI-OUT-N\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eOutdoor omnidirectional 4G antenna, N connector, 698-3800 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eANT-5G-OMNI-OUT-N \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eOutdoor omnidirectional 617 – 5950 MHz antenna, N connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003e4G-LTE-ANTM-O-3-B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e3-in-1 outdoor black antenna, 4G LTE SMA x2, GPS SMA x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eANT-3-4G2G1-O\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e3-in-1 outdoor antenna- 4G LTE TNC x2, GPS SMA x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eANT-2-4G2-O\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e2-in-1 outdoor vehicle mount antenna- 4G LTE TNC x2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eANT-5-4G2WL2G1-O \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e5-in-1 outdoor vehicle mount antenna- 4G LTE TNC x2, Wi-Fi dual band RP-TNC x2, GPS SMA x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003e5G-ANTM-O-4-B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e9-in-1 outdoor antenna- 5G Sub-6 GHz \/ 4G LTE SMA x4, Wi-Fi dual band RP-SMA x4,\u003cbr data-mce-fragment=\"1\"\u003eGPS SMA x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eOBD-II cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eOBD2-J1962YA-MF4 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eOBD-II (J1962 Type A to IR1800 cable with type 1 Y-splitting bypass harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eOBD2-J1962YB-MF4 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eOBD-II (J1962 Type B to IR1800 cable with type 2 Y-splitting bypass harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eOBD2-J1939Y2-MF4 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eOBD-II (J1939 Type 2 heavy-duty diagnostic harness for Volvo\/Mack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eOBD2-J1939Y1-MF4 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eOBD-II (J1939 Type 1 to IR1800 cable with type 1 y-splitting bypass harness and auxiliary (discrete voltage inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eOBD2-J1708Y-MF4 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eOBD-II (J1708 to IR1800 cable with type 1 y-splitting bypass harness and auxiliary (discrete voltage inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eOBD2-J1962VMB-MF4 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eJ1962-VM-Type B Volvo \u0026amp; Mack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eM-12 Connector Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIRM-1800-M12KIT\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eM12 Conversion Kit for IR1800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIRM-1800-M12KIT=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eM12 Conversion Kit for IR1800 - Spare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eCellular module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTEAP18-GL(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 18 LTE module for North America, Europe, and Asia Pacific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTEA-EA(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 6 LTE module for North America, Europe, and the Middle East\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTEA-LA(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 6 LTE module for Asia Pacific and Latin America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTE-MNA(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 4 LTE module for AT\u0026amp;T, FirstNet Ready and Verizon, US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTE-US(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 4 LTE module for AT\u0026amp;T, U.S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTE-VZ(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 4 LTE module for Verizon, U.S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTE-GB(=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 4 LTE module for Europe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTE-IN(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 4 LTE module for India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eP-LTE-JN(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eCategory 4 LTE module for Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eSSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIRM-SSD-100G(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e100-GB industrial-grade field-replaceable SSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003ePower supply and cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003ePWR-MF4-125W-AC(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eAC to DC power adapter for IR1800- 125W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-NA(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord - North America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-BR(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord - Brazil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-AU(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – Australia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-CE(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – Central Europe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-ISR(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – Israel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-ID(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord - India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-UK(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord - United Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-ITA(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – Italy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-AR(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – Argentina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-JP(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-AP(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – Asia Pacific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-CN(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-SA(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord – South Africa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eIR-PWR-G2A-SWI(= \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower Cord - Switzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eOther accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003ePower cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-PWR-15-MF4 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003ePower cable when directly connecting to a DC source (such as a vehicle battery\u003cbr data-mce-fragment=\"1\"\u003eNOTE: It is preferred to use an OBD-II cable for a quick and clean installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eRF cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L240-10-SM-TM \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eSMA(m-straight to TNC(m-straight, LMR-240-DB, 10 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L240-15-SM-TM \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eSMA(m-straight to TNC(m-straight, LMR-240-DB, 15 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L240-20-SM-TM \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eSMA(m-straight to TNC(m-straight, LMR-240-DB, 20 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eLTE-AE-MAG-SMA \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eMagnetic SMA antenna stand, SMA(f-straight to TNC(f-straight, LMR-195 plenum rated, 1 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L240-10-SM-NM \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eSMA(m-straight to N(m-straight, LMR-240-FRDB, 10 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L-10-RSP-RTP \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eRP-SMA(male to RP-SMA(female, 10 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L195-10-SM-SF \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eSMA(m to SMA(f, LMR-195, 10 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L240-20-SM-SF \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eSMA(m to SMA(f, LMR-240, 20 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-L400-20-N-N \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eN(m-straight to N(m-right angle, LMR-400-DB, 20 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eRF adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eLTE-ADPT-SM-TF\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003e SMA(m-straight to TNC(f-straight adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eAIR-ACC370-NF-NF \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eN(f-straight to N(f-straight adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eEthernet cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-ETH-S-RJ45 \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eYellow Cable for Ethernet, Straight through, RJ-45, 15 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eConsole cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCAB-USB-UB\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eUSB Type A to USB Micro-B (2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center; width: 555.5px;\" colspan=\"2\"\u003eLighting arrestors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eACC-LA-G-SM-SF \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eSMA(m to SMA(f- straight, GDT, DC to 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCGR-LA-NF-NF \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eN(f-straight to N(f-straight, GDT, DC to 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003eCGR-LA-NM-NF \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eN(f-straight to N(m-straight, GDT, DC to 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 108.297px;\"\u003e4G-ACC-OUT-LA \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 441.203px;\"\u003eTNC(f-straight to TNC(m-straight, HPF, 698 to 2700 MHz (does not support GNSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eCisco IR1821-K9 Router\u003c\/h2\u003e\n\u003cp\u003eThe Cisco IR1821-K9 is a member of the Cisco IR1800 Rugged Routers series. This router integrates 5G and Wi-Fi 6 technologies to enable the digital transformation of your mobile edge. It offers superior performance, improved security features, and versatility to facilitate digitization at the edge. The IR1800 model's modular design allows for the incorporation of new technologies, safeguarding your networking investments. It is equipped with 4GB RAM, 4x GE LAN ports, 1x Combo RJ-45\/SFP GE WAN port, 1x USB console and 1x pluggable slots.\u003c\/p\u003e\n\u003ch3\u003eQuick Specs:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4GB RAM\u003c\/li\u003e\n\u003cli\u003e4x GE LAN ports\u003c\/li\u003e\n\u003cli\u003e1x Combo RJ-45\/SFP GE WAN port\u003c\/li\u003e\n\u003cli\u003e1x RS-232 serial interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlease see the related tabs for the IR1821-K9 datasheet and compatible accessories.\u003c\/p\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013011124441,"sku":"IR1821-K9-NEW","price":1086.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/IR1821-K9_1_37ec7907-6494-4a61-b863-2f86a1610863.webp?v=1771848435","url":"https:\/\/www.aloinfousa.com.mx\/id\/products\/cisco-ir1821-k9-router-iut7b","provider":"aloinfousa.com","version":"1.0","type":"link"}