{"product_id":"juniper-ex2300-c-12p-switch-rkqej","title":"Juniper EX2300-C-12P Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eSwitch\u003c\/li\u003e\n\u003cli\u003eL3\u003c\/li\u003e\n\u003cli\u003emanaged\u003c\/li\u003e\n\u003cli\u003e12 x 10\/100\/1000 (PoE+) + 2 x Gigabit SFP \/ 10 Gigabit SFP+\u003c\/li\u003e\n\u003cli\u003erack-mountable\u003c\/li\u003e\n\u003cli\u003ePoE+ (124 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"516\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003eJuniper EX2300-C-12P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003eEX2300 Compact Fanless 12-port 10\/100\/1000BASE-T PoE+, 2 x 1\/10GbE SFP\/SFP+ (optics sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX2300-C Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eGbE Port Density\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e14 (12 access ports + 2 uplink ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10.98 x 1.72 x 9.4 in (27.9 x 4.4 x 23.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e6.99 lb (3.17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003eFanless Operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eBackplane\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e40 Gbps Virtual Chassis interconnect to link up to four switches as a single logical device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"516\" colspan=\"2\"\u003eProduct Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eAccess Port Configuration\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e12-port 10\/100\/1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eUplink Ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003eTwo SFP\/SFP+ ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePoE+ Capable Ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eHeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e1 RU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePoE+ Budget\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e124 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePower Supply Rating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e170 W AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"516\" colspan=\"2\"\u003ePower Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eMax. System Power Consumption (Input Power without PoE)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTotal PoE Power Budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e24 W AC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e124W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eAcoustic Noise in DB\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"310\"\u003e0 DB (Fanless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"774\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eEX2300-C-12P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eDRAM\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2 GB with ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eCPU\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e1.25GHz ARM CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003ePhysical Layer\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003ePhysical port redundancy: Redundant trunk group (RTG) \u003cbr data-mce-fragment=\"1\"\u003eCable diagnostics for detecting cable breaks and shorts \u003cbr data-mce-fragment=\"1\"\u003eAuto medium-dependent interface\/medium-dependent interface crossover (MDI\/MDIX) support \u003cbr data-mce-fragment=\"1\"\u003ePort speed downshift\/setting maximum advertised speed on 10\/100\/1000BASE-T ports \u003cbr data-mce-fragment=\"1\"\u003eDigital optical monitoring for optical ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003ePacket-Switching Capacities\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32 Gbps (unidirectional)\/64 Gbps (bidirectional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"774\" colspan=\"2\"\u003eSoftware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLayer 2\/Layer 3 Throughput (Mpps) (Maximum with 64 Byte Packets)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e47 Mpps (wire speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eMaximum MAC addresses in hardware: 16,000 \u003cbr data-mce-fragment=\"1\"\u003eJumbo frames: 9216 bytes \u003cbr data-mce-fragment=\"1\"\u003eNumber of VLANs supported: 4093 (2044 active VLAN) \u003cbr data-mce-fragment=\"1\"\u003eRange of possible VLAN IDs: 1-4094 \u003cbr data-mce-fragment=\"1\"\u003ePort-based VLAN \u003cbr data-mce-fragment=\"1\"\u003eMAC-based VLAN \u003cbr data-mce-fragment=\"1\"\u003eVoice VLAN \u003cbr data-mce-fragment=\"1\"\u003eLayer 2 Protocol Tunneling (L2PT) \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1ak: Multiple VLAN Registration Protocol (MVRP) \u003cbr data-mce-fragment=\"1\"\u003eCompatible with Per-VLAN Spanning Tree Plus (PVST+) \u003cbr data-mce-fragment=\"1\"\u003eRVI (Routed VLAN Interface) \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1AB: Link Layer Discovery Protocol (LLDP) \u003cbr data-mce-fragment=\"1\"\u003eLLDP-MED with VoIP integration \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1ad Q-in-Q tunneling \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1br Bridge Port Extension \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1D: Spanning Tree Protocol \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1p: CoS Prioritization \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q: VLAN Tagging\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q-in-Q: VLAN Stacking\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1s: Multiple Spanning Tree Protocol (MSTP)\u003cbr data-mce-fragment=\"1\"\u003eNumber of MST instances supported: 64\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1w: Rapid Spanning Tree Protocol (RSTP)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1X: Port Access Control\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3: 10BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3u: 100BASE-TX\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ab: 1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3z: 1000BASE-X\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3af: PoE\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3at: PoE+\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ad: Link Aggregation Control Protocol (LACP)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3x: Pause Frames\/Flow Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLayer 3 Features: IPv4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eMaximum number of ARP entries: 1,500\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv4 unicast routes in hardware: 512\u003cbr data-mce-fragment=\"1\"\u003eprefixes; 4,096 host routes\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv4 multicast routes in hardware: 2,048\u003cbr data-mce-fragment=\"1\"\u003egroups; 2,048 multicast routes\u003cbr data-mce-fragment=\"1\"\u003eRouting Protocols: RIP v1\/v2, OSPF v1\/v2\u003cbr data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003eRouting policy\u003cbr data-mce-fragment=\"1\"\u003eBidirectional Forwarding Detection (BFD) with slow timers (\u0026gt; 3\u003cbr data-mce-fragment=\"1\"\u003esec)\u003cbr data-mce-fragment=\"1\"\u003eIP directed broadcast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLayer 3 Features: IPv6\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eMaximum number of Neighbor Discovery (ND) entries: 1,500\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv6 unicast routes in hardware: 512\u003cbr data-mce-fragment=\"1\"\u003eprefixes; 2,048 host routes\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv6 multicast routes in hardware: 1,024\u003cbr data-mce-fragment=\"1\"\u003egroups; 1,024 multicast routes\u003cbr data-mce-fragment=\"1\"\u003eNeighbor discovery, system logging, Telnet, SSH, SNMP,\u003cbr data-mce-fragment=\"1\"\u003eNetwork Time Protocol (NTP), Domain Name System (DNS)\u003cbr data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003eRouting protocols: RIPng, OSPF v3\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eAccess Control Lists (ACLs) (Junos OS Firewall Filters)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003ePort-based ACL (PACL)256 ingress; 256 egress\u003cbr data-mce-fragment=\"1\"\u003eVLAN-based ACL (VACL)256 ingress; 256 egress\u003cbr data-mce-fragment=\"1\"\u003eRouter-based ACL (RACL)256 ingress; 512 egress\u003cbr data-mce-fragment=\"1\"\u003eACL entries (ACE) in hardware per system: 2,000\u003cbr data-mce-fragment=\"1\"\u003eACL counter for denied packets\u003cbr data-mce-fragment=\"1\"\u003eACL counter for permitted packets\u0026gt;\u003cbr data-mce-fragment=\"1\"\u003eAbility to add\/remove\/change ACL entries in middle of list\u003cbr data-mce-fragment=\"1\"\u003e(ACL editing)\u003cbr data-mce-fragment=\"1\"\u003eL2-L4 ACL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eAccess Security\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eMAC limiting\u003cbr data-mce-fragment=\"1\"\u003eAllowed MAC addressesconfigurable per port\u003cbr data-mce-fragment=\"1\"\u003eMAC limiting\u003cbr data-mce-fragment=\"1\"\u003eAllowed MAC addressesconfigurable per port\u003cbr data-mce-fragment=\"1\"\u003eSticky MAC (persistent MAC address learning)\u003cbr data-mce-fragment=\"1\"\u003eDynamic ARP inspection (DAI)\u003cbr data-mce-fragment=\"1\"\u003eProxy ARP\u003cbr data-mce-fragment=\"1\"\u003eStatic ARP support\u003cbr data-mce-fragment=\"1\"\u003eDHCP snooping\u003cbr data-mce-fragment=\"1\"\u003e802.1X port-based\u003cbr data-mce-fragment=\"1\"\u003e802.1X multiple supplicants\u003cbr data-mce-fragment=\"1\"\u003e802.1X with VLAN assignment\u003cbr data-mce-fragment=\"1\"\u003e802.1X with authentication bypass access (based on host MAC\u003cbr data-mce-fragment=\"1\"\u003eaddress)\u003cbr data-mce-fragment=\"1\"\u003e802.1X with VoIP VLAN support\u003cbr data-mce-fragment=\"1\"\u003e802.1X dynamic access control list (ACL) based on RADIUS\u003cbr data-mce-fragment=\"1\"\u003eattributes\u003cbr data-mce-fragment=\"1\"\u003e802.1X Supported EAP types: Message Digest 5 (MD5),\u003cbr data-mce-fragment=\"1\"\u003eTransport Layer Security (TLS), Tunneled Transport Layer\u003cbr data-mce-fragment=\"1\"\u003eSecurity (TTLS), Protected Extensible Authentication Protocol\u003cbr data-mce-fragment=\"1\"\u003e(PEAP)\u003cbr data-mce-fragment=\"1\"\u003eIPv6 RA Guard\u003cbr data-mce-fragment=\"1\"\u003eIPv6 Neighbor Discovery Inspection\u003cbr data-mce-fragment=\"1\"\u003eCaptive Portal\u003cbr data-mce-fragment=\"1\"\u003eStatic MAC authentication\u003cbr data-mce-fragment=\"1\"\u003eMAC-RADIUS\u003cbr data-mce-fragment=\"1\"\u003eControl plane DoS protection\u003cbr data-mce-fragment=\"1\"\u003eFallback Authentication\u003cbr data-mce-fragment=\"1\"\u003eTrusted Network Connect (TNC) certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eHigh Availability\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eLink Aggregation\u003cbr data-mce-fragment=\"1\"\u003e802.3ad (LACP) support:\u003cbr data-mce-fragment=\"1\"\u003e- Number of LAGs supported: 128\u003cbr data-mce-fragment=\"1\"\u003e- Maximum number of ports per LAG: 8\u003cbr data-mce-fragment=\"1\"\u003eTagged ports support in LAG\u003cbr data-mce-fragment=\"1\"\u003eUplink failure detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eLayer 2 QoS\u003cbr data-mce-fragment=\"1\"\u003eLayer 3 QoS\u003cbr data-mce-fragment=\"1\"\u003eIngress policing: 2 rate 3 color\u003cbr data-mce-fragment=\"1\"\u003eHardware queues per port: 8\u003cbr data-mce-fragment=\"1\"\u003eScheduling methods (egress): Strict Priority (SP), shaped-deficit\u003cbr data-mce-fragment=\"1\"\u003eweighted round-robin (SDWRR)\u003cbr data-mce-fragment=\"1\"\u003e802.1p: DSCP\/IP precedence trust and marking\u003cbr data-mce-fragment=\"1\"\u003eL2-L4 classification criteria: Interface, MAC address, Ethertype,\u003cbr data-mce-fragment=\"1\"\u003e802.1p, VLAN, IP address, DSCP\/IP precedence, TCP\/UDP\u003cbr data-mce-fragment=\"1\"\u003eport numbers\u003cbr data-mce-fragment=\"1\"\u003eCongestion avoidance capabilities: Tail drop and WRED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eMulticast\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eInternet Group Management Protocol (IGMP) snooping\u003cbr data-mce-fragment=\"1\"\u003eentries: 2,000\u003cbr data-mce-fragment=\"1\"\u003eIGMP: v1, v2, v3\u003cbr data-mce-fragment=\"1\"\u003eIGMP snooping\u003cbr data-mce-fragment=\"1\"\u003ePIM sparse mode (PIM SM), PIM source-specific multicast (PIM\u003cbr data-mce-fragment=\"1\"\u003eSSM), PIM dense mode (PIM DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eDevice Management and Operations\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eJunos OS CLI\u003cbr data-mce-fragment=\"1\"\u003eDevice Management and Operations\u003cbr data-mce-fragment=\"1\"\u003eJunos OS CLI\u003cbr data-mce-fragment=\"1\"\u003eJunos Web interface (J-Web)\u003cbr data-mce-fragment=\"1\"\u003eOut-of-band management: Serial, 10\/100BASE-T Ethernet\u003cbr data-mce-fragment=\"1\"\u003eASCII configuration\u003cbr data-mce-fragment=\"1\"\u003eRescue configuration\u003cbr data-mce-fragment=\"1\"\u003eConfiguration rollback\u003cbr data-mce-fragment=\"1\"\u003eImage rollback\u003cbr data-mce-fragment=\"1\"\u003eSimple Network Management Protocol (SNMP): v1, v2c, v3\u003cbr data-mce-fragment=\"1\"\u003eRemote monitoring (RMON) (RFC 2819) Groups 1, 2, 3, 9\u003cbr data-mce-fragment=\"1\"\u003eNetwork Time Protocol (NTP)\u003cbr data-mce-fragment=\"1\"\u003eDHCP server\u003cbr data-mce-fragment=\"1\"\u003eDHCP client and DHCP proxy\u003cbr data-mce-fragment=\"1\"\u003eDHCP relay and helper\u003cbr data-mce-fragment=\"1\"\u003eRADIUS authentication\u003cbr data-mce-fragment=\"1\"\u003eTACACS+ authentication\u003cbr data-mce-fragment=\"1\"\u003eSSHv2\u003cbr data-mce-fragment=\"1\"\u003eSecure copy\u003cbr data-mce-fragment=\"1\"\u003eHTTP\/HTTPs\u003cbr data-mce-fragment=\"1\"\u003eDNS resolver\u003cbr data-mce-fragment=\"1\"\u003eSystem log logging\u003cbr data-mce-fragment=\"1\"\u003eTemperature sensor\u003cbr data-mce-fragment=\"1\"\u003eConfiguration backup via FTP\/secure copy\u003cbr data-mce-fragment=\"1\"\u003eInterface range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eManagement and Analytics Platforms\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eJuniper Mist Wired Assurance for Campus \u003cbr data-mce-fragment=\"1\"\u003eJunos Space® Network Director for Campus \u003cbr data-mce-fragment=\"1\"\u003eJunos Space® Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eup to 5.000 ft (1524 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eup to 16,000 ft (4877 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10% to 85% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSafety Certifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eUL-UL60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eC-UL to CAN\/CSA 22.2 No.60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eTUV\/GS to EN 60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eCB-IEC60950-1 (Second Edition with all country deviations)\u003cbr data-mce-fragment=\"1\"\u003eEN 60825-1 (Second Edition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eElectromagnetic Compatibility Certifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eFCC 47CFR Part 15 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022 Class A\u003cbr data-mce-fragment=\"1\"\u003eICES-003 Class A\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eEN 300386\u003cbr data-mce-fragment=\"1\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTelecom Quality Management\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eTL9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTelco\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eCLEI code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"434\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"434\" colspan=\"2\"\u003eAccessories and License Upgrade PIDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-CBL-CON-USB\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eConsole cable with USB Type A and mini-B connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX2300-C-CBL-GRD\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eCable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX2300-C-MGNT-MNT\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eMagnet mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX2300-C-RMK\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eRack-mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eSubscription Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eS-EX-A-C1-3\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches, 3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eS-EX-A-C1-5\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches, 5 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eS-EX-A-C1-3-COR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches with SVC CORE support, 3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eS-EX-A-C1-5-COR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches with SVC CORE support, 5 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003ePerpetual Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eS-EX-A-C2-P\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSoftware, EX Series Advanced license, Class 2 Perpetual license for 12-port switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-12-EFL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eEnhanced Feature License for EX2300 12 port switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"434\" colspan=\"2\"\u003eOptics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-10GE-USR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10-Gigabit Ethernet Ultra Short Reach Optics, 850 nm for 10m on OM1, 20m on OM2, 100m on OM3 multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-10GE-DAC-1M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10-Gigabit Ethernet Direct Attach Copper (twinax copper cable), 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10GBASE-LR; LC connector; 1310 nm; 10km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10GBASE-LR; LC connector; 1310 nm; 10km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-10GE-DAC-3M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10-Gigabit Ethernet Direct Attach Copper (twinax copper cable), 3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-10GE-DAC-5M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10-Gigabit Ethernet Direct Attach Copper (twinax copper cable), 5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-1GE-SX\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-SX; LC connector; 850 nm; 550m reach on multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-1GE-SX-ET\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eExtended Temperature SFP 1000BASE-SX; LC connector; 850 nm; 550m reach on multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-1GE-LX\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-LX; LC connector; 1310 nm; 10 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-1GE-LH\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-LH Gigabit Ethernet Optics, 1550 nm for 70 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-1GE-T\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 10\/100\/1000BASE-T Copper Transceiver Module for up to 100m transmission on Category\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-1GE-LX40K\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-LX Gigabit Ethernet Optics, 1310 nm for 40 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE10KT13R14\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1310 nm\/Rx 1490 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE10KT14R13\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1490 nm\/Rx 1310 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE10KT13R15\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1310 nm\/Rx 1550 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE10KT15R13\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1550 nm\/Rx 1310 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE40KT13R15\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1310 nm\/Rx 1550 nm for 40 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE40KT15R13\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1550 nm\/Rx 1310 nm for 40 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1470\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1470 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1490\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1490 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1510\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1510 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1530\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1530 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1550\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1550 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1570\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1570 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1590\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1590 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eEX-SFP-GE80KCW1610\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1610 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003cp\u003eThe Juniper Networks EX2300-C Ethernet Switch delivers a compact, silent, and power-efficient platform for low-density branch deployments and commercial access or enterprise workgroup environments outside the wiring closet. Featuring 12 10\/100\/1000BASE-T access ports and two 10GbE uplink ports with and without Power over Ethernet (PoE\/PoE+) in a fanless design, the EX2300-C switches deliver a powerful solution for supporting services such as unified communications, IP telephony, closed circuit television (CCTV), and other applications in office, classroom, hospitality, and other space and wiring-constrained environments.\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013294633177,"sku":"EX2300-C-12P-NEW","price":640.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ex2300-c-12p_1_d556b3f0-0c3e-4995-b976-bde3863c890a.webp?v=1771853523","url":"https:\/\/www.aloinfousa.com.mx\/products\/juniper-ex2300-c-12p-switch-rkqej","provider":"aloinfousa.com","version":"1.0","type":"link"}