{"product_id":"axis-a9188-network-i-o-relay-module-0820-001","title":"AXIS A9188 Network I\/O Relay Module (0820-001","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eIntelligent module with supervised inputs, 8 I\/Os with configurable levels, 8 form C relays, 12 and 24 V DC output, PoE or 8–28 V DC input, Axis open protocols – VAPIX and ACAP\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 1108pt;\" width=\"1478\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 25786; width: 554pt;\" width=\"739\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 25786; width: 554pt;\" width=\"739\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAXIS A9188 Network I\/O Relay Module (0820-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eIntelligent network I\/O relay module with 8 configurable I\/Os and 8 form C relays, ideal for expanding Axis systems with additional inputs and outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Options\u003c\/td\u003e\n\u003ctd\u003eSupports PoE (IEEE 802.3af Class 3 \/ 802.3at Class 4 or 8–28 V DC input for flexible installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003eProvides 12 V and 24 V DC output to power connected I\/O devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE-out Limits\u003c\/td\u003e\n\u003ctd\u003eMaximum shared power out: 3.6 W (Class 3 or 12 W (Class 4 \/DC power input.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Ports\u003c\/td\u003e\n\u003ctd\u003e8 supervised inputs\/outputs with configurable levels for custom applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd\u003e8 form C relays for enhanced control and integration with third-party systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration\u003c\/td\u003e\n\u003ctd\u003eCompatible with AXIS A1001 Network Door Controller; ideal for elevator and floor management applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eSupports Axis open protocols VAPIX® and AXIS Camera Application Platform (ACAP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003eSupported by AXIS Camera Station and third-party software via VAPIX.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators for real-time monitoring of input and output status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsage Application\u003c\/td\u003e\n\u003ctd\u003eExtends Axis product functionality where additional I\/Os or relays are needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e−30 °C to 55 °C (−22 °F to 131 °F; outdoor use requires AXIS T98A15-VE Cabinet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connectivity\u003c\/td\u003e\n\u003ctd\u003eEthernet interface for seamless system integration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eSupervised inputs provide tamper detection and status monitoring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDesigned for indoor installation (standard DIN-rail mount.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e43 × 186 × 120 mm (W × H × D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e500 g (1.1 lb.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 1108pt;\" width=\"1478\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 25786; width: 554pt;\" width=\"739\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 25786; width: 554pt;\" width=\"739\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e8–28 V DC or PoE IEEE 802.3af Class 3 \/ 802.3at Class 4.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003e12 V and 24 V DC outputs for connected devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE-out Power\u003c\/td\u003e\n\u003ctd\u003eMax 3.6 W (Class 3 or 12 W (Class 4 \/DC input shared power out.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003e8 configurable supervised inputs\/outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e8 form C relays for expanded system control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eVAPIX® and ACAP for integration with Axis and third-party platforms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−30 °C to 55 °C (−22 °F to 131 °F; outdoor operation requires AXIS T98A15-VE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators for input\/output and power status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet 10\/100 Mbps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eIndoor DIN-rail mounting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e43 × 186 × 120 mm (W × H × D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e500 g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003eAXIS A9188 Network I\/O Relay Module (0820-001\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003eAXIS A9188 Network I\/O Relay Module is an intelligent module with 8 configurable I\/Os and 8 form C relays supporting supervised inputs. It uses open APIs including VAPIX for software integration and works seamlessly with AXIS A1001 Network Door Controller for applications such as elevator control and floor management. Supported by AXIS Camera Station and third-party software, the module provides 12 V and 24 V DC outputs for connected I\/O devices and offers maximum PoE-out power of 3.6 W (Class 3 or 12 W (Class 4 \/DC input. Powered by 8–28 V DC or PoE IEEE 802.3af Class 3 \/ 802.3at Class 4.\u003c\/p\u003e","brand":"Axis","offers":[{"title":"Default Title","offer_id":48007453409497,"sku":"0820-001-NEW","price":852.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/0820-001_1.webp?v=1771682672","url":"https:\/\/www.aloinfousa.com.mx\/pt-br\/products\/axis-a9188-network-i-o-relay-module-0820-001","provider":"aloinfousa.com","version":"1.0","type":"link"}