{"product_id":"cisco-iem-3000-8fm-expansion-module-zbmt2","title":"Cisco IEM-3000-8FM Expansion Module","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eExpansion module\u003c\/li\u003e\n\u003cli\u003e10\/100 Ethernet x 8\u003c\/li\u003e\n\u003cli\u003efor P\/N: IE-3000-4TC\u003c\/li\u003e\n\u003cli\u003eIE-3000-8TC\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"509\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"309\"\u003eCisco IEM-3000-8FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"309\"\u003eExpansion module, 10\/100 Ethernet x 8, for P\/N: IE-3000-4TC, IE-3000-8TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIndustrial Ethernet 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eExpansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eConfigurations\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"309\"\u003eExpansion Fiber module for Cisco IE-3000-4TC and IE-3000-8TC switches\u003cbr data-mce-fragment=\"1\"\u003e8 100 FX ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eSupported Products\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"309\"\u003eIE-3000-4TC and IE-3000-8TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"309\"\u003e3.5W x 5.8H x 4.4D (89mm W x 147mm H x 112mm D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e3.2 lb (1.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eMaximum power consumption\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"309\"\u003e10.1W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eMean Time Between Failures (MTBF)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"309\"\u003e264,689\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties][specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"753\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEM-3000-8FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e-40C to +75C\u003cbr data-mce-fragment=\"1\"\u003e-40C to +70C (Vented Enclosure 40 LFM Air Flow)\u003cbr data-mce-fragment=\"1\"\u003e-40C to +60C (Sealed Enclosure 0 LFM Air Flow)\u003cbr data-mce-fragment=\"1\"\u003e-24C to +75C (Fan or Blower equipped Enclosure 200 LFM Air Flow)\u003cbr data-mce-fragment=\"1\"\u003e-40C to +85C (IEC 60068-2-2 Environmental Type Testing 16 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUp to 13,000 ft (3963m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUp to 15,000 ft (4573m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eStandard safety certifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUL 60950-1\u003cbr data-mce-fragment=\"1\"\u003eCSA C22.2 No. 60950-1\u003cbr data-mce-fragment=\"1\"\u003eTUV\/GS to EN 60950-1\u003cbr data-mce-fragment=\"1\"\u003eCB to IEC 60950-1 with all country deviations\u003cbr data-mce-fragment=\"1\"\u003eNOM\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eElectromagnetic emissions\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eFCC Part 15 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22\u003cbr data-mce-fragment=\"1\"\u003eCISPR11\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS 3548 Class A\u003cbr data-mce-fragment=\"1\"\u003eCNS 13438 Class A\u003cbr data-mce-fragment=\"1\"\u003eKN 22 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eElectromagnetic immunity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 24\u003cbr data-mce-fragment=\"1\"\u003eKN 24\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-2 (Electro Static Discharge)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-3 (Radiated Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-4 (Fast Transients)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-5 (Surge)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-6 (Conducted Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-8 (Power Frequency Magnetic Field Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-9 (Pulse Magnetic Field Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-10 (Oscillatory Magnetic Field Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-11 (AC power Voltage Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-16 (Low Frequency Conducted CM Disturbances)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-17 (Ripple on DC Input Power)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-18 (Damped Oscillatory Wave)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-29 (Voltage Dips Immunity, DC power)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90 (Surge)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90.1 (Fast Transients)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90.2 (Radiated Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90.3 (Electro Static Discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMechanical stability\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEC 60628-2-27 Shock 20g (operational), 30g (nonoperational)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIndustry specifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eEN 61131-2 Programmable Controllers (EMC\/EMI, environmental, mechanical)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 1613 Power Station and Substation Networking Devices\u003cbr data-mce-fragment=\"1\"\u003eIEC 61850-3 Power Station and Substation Communication Networks and Systems\u003cbr data-mce-fragment=\"1\"\u003eEN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use - EMC\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-1 Immunity for Light Industrial Environments\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-2 Immunity for Industrial Environments\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-4 Emissions for Industrial Environments\u003cbr data-mce-fragment=\"1\"\u003eTS 61000-6-5 EMC Immunity for Power Station and Substation\u003cbr data-mce-fragment=\"1\"\u003eEN 50155 Railway, Electronic Equipment on Rolling Stock (EMI\/EMC, environmental, mechanical)\u003cbr data-mce-fragment=\"1\"\u003eEN 50121-3-2 Railway, Electromagnetic Compatibility on Rolling Stock\u003cbr data-mce-fragment=\"1\"\u003eEN 50121-4 Railway, Emission and Immunity of Signaling and Telecommunications Apparatus\u003cbr data-mce-fragment=\"1\"\u003eEN 60945 Maritime Navigation and Radio-communication Equipment and Systems\u003cbr data-mce-fragment=\"1\"\u003eIEC 60533 Shipboard Electrical and Electronic Installation EMC\u003cbr data-mce-fragment=\"1\"\u003eMarine Type Approval (BV, DNV, Korean Register, Lloyd Register)\u003cbr data-mce-fragment=\"1\"\u003eNEMA TS-2 (EMC, environmental, mechanical)\u003cbr data-mce-fragment=\"1\"\u003eABB Industrial IT certification\u003cbr data-mce-fragment=\"1\"\u003eODVA Industrial EtherNet\/IP support\u003cbr data-mce-fragment=\"1\"\u003ePROFINETv2 support\u003cbr data-mce-fragment=\"1\"\u003eDirective 2011\/65\/EU RoHS\u003cbr data-mce-fragment=\"1\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHazardous locations\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUL\/CSA 60079-0, -15 (Class 1, Div 2 A-D) (requires cabinet enclosure)\u003cbr data-mce-fragment=\"1\"\u003eEN 60079-0, -15 ATEX Certification (Class 1, Zone 2 A-D) (requires cabinet enclosure)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60079-0, -15 (Test report only) (requires cabinet enclosure)\u003cbr data-mce-fragment=\"1\"\u003eUL 508\u003cbr data-mce-fragment=\"1\"\u003eCSA C22.2 No. 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRelative humidity: 5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eCisco IEM-3000-8FM= Expansion Module\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Cisco Industrial Ethernet 3000 Series is designed to comply with a wide range of Industrial Ethernet specifications, making it an ideal choice for industrial automation, ITS, substation, railway, and other markets. The IEM-3000-8FM= is an expansion Fx fiber module for Cisco IE-3000-4TC, IE-3000-8TC, IE-3000-4TC-E, and IE-3000-8TC-E switches.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eKey Features:\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e8 x 100-FX ports\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\" style=\"font-style: inherit; font-weight: inherit;\" data-mce-style=\"font-style: inherit; font-weight: inherit;\"\u003eCabling Type : Ethernet 100base-\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFor detailed specifications, refer to the IEM-3000-8FM= datasheet in the tabs.\u003c\/p\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013312950489,"sku":"IEM-3000-8FM-NEW","price":390.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/IEM-3000-8FM_1_5da6f7c4-a518-4d4a-849a-1f2a892a7657.webp?v=1771853904","url":"https:\/\/www.aloinfousa.com.mx\/pt-br\/products\/cisco-iem-3000-8fm-expansion-module-zbmt2","provider":"aloinfousa.com","version":"1.0","type":"link"}