{"product_id":"endress-hauser-5w4c-proline-promag-w400-electromagnetic-flowmeter","title":"Endress+Hauser 5W4C Proline Promag W400 Electromagnetic Flowmeter","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser Proline Promag W400 Electromagnetic Flowmeter is a versatile standard flowmeter for the water and wastewater industry.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMax. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm\/s (0.04 in\/s)\u003cbr\u003eVolume flow (option): ±0.2 % o.r. ± 2 mm\/s (0.08 in\/s), Flat Spec Measuring range 0.5 m3\/h to 263000 m3\/h (2.5gal\/min to 1665 Mgal\/d) Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)\u003cbr\u003eLiner material polyurethane: –20 to +50 °C (–4 to +122 °F)\u003cbr\u003eLiner material PTFE: –20 to +90 °C (–4 to +194 °F) Max. process pressure PN 40, Class 300, 20K Wetted materials Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)\u003cbr\u003eLiner material polyurethane: –20 to +50 °C (–4 to +122 °F)\u003cbr\u003eLiner material PTFE: –20 to +90 °C (–4 to +194 °F)\u003cbr\u003eElectrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum\u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eWith its international approvals for custody transfer as well as drinking water, Promag W serves the broadest variety of applications. It is available as both compact or remote version. Promag W 400 saves time and costs thanks to the broad functionality of its transmitter optimized for Water \u0026amp; Wastewater. In addition, Heartbeat Technology enables measurement reliability and compliant verification.\u003cbr\u003e\u003cbr\u003e* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity\u003cbr\u003e* Ideal for water measurement , e.g. drinking water, utility water and industrial\/municipal wastewater\u003c\/p\u003e\u003cp\u003e\u003cbr\u003eDevice properties\u003cbr\u003e* International drinking water approvals\u003cbr\u003e* Degree of protection IP68 (Type 6P enclosure)\u003cbr\u003e* Approved for custody transfer to MI-001\/OIML R49\u003cbr\u003e* Transmitter housing made of durable polycarbonate or aluminium\u003cbr\u003e* WLAN access\u003cbr\u003e* Integrated data logger: measured values monitoring \u003cbr\u003e \u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss\u003cbr\u003e* Flexible engineering – sensor with fixed or lap-joint process connections\u003cbr\u003e* Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation\u003cbr\u003e* Improved plant availability – sensor compliant with industry-specific requirements\u003cbr\u003e* Safe operation – no need to open the device\u003cbr\u003e* Time-saving local operation without additional software and hardware – integrated web server\u003cbr\u003e* Integrated verification and build-up detection – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProline Promag W 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eElectromagnetic \u003cbr\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVersatile standard flowmeter for the water and wastewater industry. \u003cbr\u003eReliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss. \u003cbr\u003eIdeal for water measurement, e.g. drinking water, utility water and industrial\/municipal wastewater.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFlexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection \u003cbr\u003efor underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements. \u003cbr\u003eInternational drinking water approvals. Degree of protection IP68 (Type 6P enclosure). Approved for custody transfer to \u003cbr\u003eMI-001\/OIML R49.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSafe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation \u003cbr\u003ewithout additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. \u003cbr\u003eTransmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal diameter range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 25 to 3000(1 to 120\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiner material hard rubber: 0 to +80 °C (+32 to +176 °F) \u003cbr\u003eLiner material polyurethane: –20 to +50 °C (–4 to +122 °F) \u003cbr\u003eLiner material PTFE: –20 to +90 °C (–4 to +194 °F) \u003cbr\u003eElectrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, conductivity, mass flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. measurement error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (standard): ±0.5 % o.r. ± 1 mm\/s (0.04 in\/s) \u003cbr\u003eVolume flow (option): ±0.2 % o.r. ± 2 mm\/s (0.08 in\/s), Flat Spec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0.5 m3\/h to 263000 m3\/h (2.5gal\/min to 1665 Mgal\/d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. process pressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 40, Class 300, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium temperature range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiner material hard rubber: 0 to +80 °C (+32 to +176 °F) \u003cbr\u003eLiner material polyurethane: –20 to +50 °C (–4 to +122 °F) \u003cbr\u003eLiner material PTFE: –20 to +90 °C (–4 to +194 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient temperature range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiner material hard rubber: 0 to +80 °C (+32 to +176 °F) \u003cbr\u003eLiner material polyurethane: –20 to +50 °C (–4 to +122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor housing material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 25 to 300 (1 to 12\"): AlSi10Mg, coated \u003cbr\u003eDN 25 to 3000 (1 to 78\"): Carbon steel with protective varnish \u003cbr\u003eSensor connection housing (standard): AlSi10Mg, coated \u003cbr\u003eSensor connection housing (option): Polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter housing material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePolycarbonat; AlSi10Mg, coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version (standard): IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version (option): IP68, type 6P enclosure, with protective varnish \u003cbr\u003eaccording to EN ISO 12944 C5‐M\/Im1\/Im2\/Im3 \u003cbr\u003eTransmitter remote version: IP66\/67, Type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display, web browser and operating tools possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3 ouputs: \u003cbr\u003e0‐20 mA\/4‐20 mA HART (active) \u003cbr\u003ePulse\/frequency\/switch output (passive) \u003cbr\u003ePulse\/frequency output (passive) \u003cbr\u003eSwitch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStatus input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS DP, EtherNet\/IP, Modbus RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAC 100…240 V \/ AC\/DC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous area approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ecCSAus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological approvals and certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025), NAMUR \u003cbr\u003eCustody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure approvals and certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHygienic approvals and certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrinking water approval: ACS, KTW\/W270, NSF 61, WRAS BS 6920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020364034265,"sku":null,"price":2500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_5W4C_Proline_Promag_W_400_Electromagnetic_Flowmeter.png?v=1771970542","url":"https:\/\/www.aloinfousa.com.mx\/pt-br\/products\/endress-hauser-5w4c-proline-promag-w400-electromagnetic-flowmeter","provider":"aloinfousa.com","version":"1.0","type":"link"}