{"product_id":"endresshauser-capacitance-point-level-detection-minicap-ftc262","title":"Endress+Hauser Capacitance Point Level Detection Minicap FTC262","description":"\u003cstyle\u003e#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:587px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin-top:0;margin-left:0;width:750px;height:587px}#detail_decorate_root .magic-3{overflow:hidden;width:750px;height:73px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-4{margin-top:0;margin-left:0;width:750px;height:73px}#detail_decorate_root .magic-5{width:446px}#detail_decorate_root .magic-6{overflow:hidden;width:446px;height:356.8px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-7{margin-top:-4.757333333333333px;margin-left:26.165333333333333px;width:361px;height:361px}#detail_decorate_root .magic-8{width:300px;display:flex;flex-direction:column;margin-right:0;margin-left:4px}#detail_decorate_root .magic-9{font-size:20px}#detail_decorate_root .magic-10{vertical-align:top}#detail_decorate_root .magic-11{vertical-align:top;display:inline-block;padding-right:4px;width:50%;box-sizing:border-box;margin-bottom:-4px;padding-left:4px;margin-top:-4px}#detail_decorate_root .magic-12{padding:0;margin:0}#detail_decorate_root .magic-13{padding:0;margin:0;color:#333;font-size:14px;line-height:20px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-14{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-15{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-16{white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-17{overflow:hidden;width:750px;height:75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-18{margin-top:0;margin-left:0;width:750px;height:75px}#detail_decorate_root .magic-19{width:750px;border-collapse:collapse}#detail_decorate_root .magic-20{min-height:28px;padding:5px 10px;width:259px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-21{min-height:28px;padding:5px 10px;width:442px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-22{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-23{overflow:hidden;width:750px;height:1078px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-24{margin-top:0;margin-left:0;width:750px;height:1078px}#detail_decorate_root .magic-25{overflow:hidden;width:750px;height:814px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-26{margin-top:0;margin-left:0;width:750px;height:814px}#detail_decorate_root .magic-27{overflow:hidden;width:750px;height:758px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-28{margin-top:0;margin-left:0;width:750px;height:758px}#detail_decorate_root .magic-29{overflow:hidden;width:750px;height:583px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-30{margin-top:0;margin-left:0;width:750px;height:583px}#detail_decorate_root .magic-31{overflow:hidden;width:750px;height:893px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-32{margin-top:0;margin-left:0;width:750px;height:893px}#detail_decorate_root .magic-33{overflow:hidden;width:750px;height:675px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-34{margin-top:0;margin-left:0;width:750px;height:675px}#detail_decorate_root .magic-35{overflow:hidden;width:750px;height:76px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-36{margin-top:0;margin-left:0;width:750px;height:76px}#detail_decorate_root .magic-37{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}\u003c\/style\u003e\n\u003cdiv data-magic-global=\"%7B%22bizId%22%3A2217607044645%2C%22pageId%22%3A200112122431%2C%22siteId%22%3A10100897032%7D\" id=\"detail_decorate_root\"\u003e\n\u003cdiv module-id=\"201246261774\" module-title=\"detailSingleImage\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201246261776\" module-title=\"detailHorizontalImageText\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eDesigned for light bulk solids.\u003c\/div\u003e\n\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e* Process temperature\u003cbr\u003e-40°C...+80°C\u003cbr\u003e(-40°F ...+176 °F)\u003cbr\u003e* Process pressure \/ max. overpressure limit\u003cbr\u003e-1 ... 6 bar(-14.5 ... 90 psi)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201246261777\" module-title=\"detailDoubleTitleParagraph\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eField of application\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eMinicap FTC262 is a simple and cost-effective rope probe for point level detection in bulk solids, particularly suited to\u003cbr\u003eapplications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g.\u003cbr\u003egrain products, flour, milk powder, animal feed, cement, chalk or gypsum.\u003cbr\u003e\u003cbr\u003eFor point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6.\u003cbr\u003eTypical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.\u003cbr\u003e* Process connection: Threads\u003cbr\u003e* Temperature: -40 to +80°C (-40 to +176°F)\u003cbr\u003e* Pressure: -1 to +6bar (-14.5 to +90psi)\u003cbr\u003e* Sensor length: 500mm (20\") to 6,000mm (236\")\u003cbr\u003e* International explosion protection certificates, overfill prevention WHG\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e * Simple mounting and commissioning without calibration\u003cbr\u003e* Mechanical safety, cost-efficiency and long operating life due to no wearing parts\u003cbr\u003e* High operational safety and reliability due to active build-up compensation\u003cbr\u003e* Optimized storage by simply shortening the rope probe on site\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201246261778\" module-title=\"detailSingleImage\" render=\"true\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv module-id=\"201246261778\" module-title=\"detailSingleImage\" render=\"true\"\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201246261778\" module-title=\"detailSingleImage\" render=\"true\"\u003e\u003c\/div\u003e\n\u003cdiv module-id=\"201246261779\" module-title=\"detailTableHorizontal\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eitem\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003evalue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eGrade\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eIndustrial\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eWarranty\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e1 Year\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCustomized support\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eOEM\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePlace of Origin\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eGermany\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eBrand Name\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eEndress+Hauser\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eModel Number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCapacitance \u003cbr\u003ePoint level detection\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMode\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMinicap FTC262\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMeasuring Principle\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCapacitive Solid\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCharacteristic \/ Application\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eNo calibration on start-up \u003cbr\u003eActive build-up compensation \u003cbr\u003eMechanically robust \u003cbr\u003eThe rope probe can be shortened \u003cbr\u003e(optimum matching to the measuring point)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSpecialities\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eRope shortening parts to be supplied by the customer\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSupply \/ Communication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e10,8 ... 45V DC, DC-PNP 3-wire \u003cbr\u003e20 ... 253V AC, or \u003cbr\u003e20 ... 55V DC, Relay output\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eAmbient Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e-40°C...+70 °C(-40°F...+158°F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProcess Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e-40°C...+80°C \u003cbr\u003e(-40°F ...+176 °F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProcess Pressure \/ Max. Overpressure Limit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e-1 ... 6 bar(-14.5 ... 90 psi)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMain Wetted Parts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePPS = Polyphenylene sulphide \u003cbr\u003e(glass fibre content approx. 40%)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMax. Tensile Strength\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e3000 N\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProcess Connection\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eR 1 1\/2 \u003cbr\u003eNPT 1 1\/2\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSensor Length\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003emin. 500 mm (20\"), max 6000 mm (236\")\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCommunication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePNP transistor output \u003cbr\u003eRelay output (potential-free \u003cbr\u003echange-over contact \/ SPDT)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCertificates \/ Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eATEX , IEC Ex, FM, CSA, NEPSI, UK Ex\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eOptions\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eAluminium Housing\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eApplication Limits\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSolids, grain size max. 30 mm (1.2\"), \u003cbr\u003eDK min 1,5 \u003cbr\u003eFlexural strength 1400 N (at probe tip)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201246261781\" module-title=\"detailSellerRecommend\" render=\"true\"\u003e\u003c\/div\u003e\n\u003cdiv module-id=\"201246261789\" module-title=\"detailTextContent\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48885728903385,"sku":null,"price":1920.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_Capacitance_Point_Level_Detection_Minicap_FTC262_28c8a520-c1cd-4ed8-b1f6-54dc89989dca.png?v=1783105817","url":"https:\/\/www.aloinfousa.com.mx\/pt-br\/products\/endresshauser-capacitance-point-level-detection-minicap-ftc262","provider":"aloinfousa.com","version":"1.0","type":"link"}