{"product_id":"juniper-ex4650-48y-dc-afi-switch-39by7","title":"Juniper EX4650-48Y-DC-AFI Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003e48Y\u003c\/li\u003e\n\u003cli\u003eSwitch\u003c\/li\u003e\n\u003cli\u003eL3\u003c\/li\u003e\n\u003cli\u003eManaged\u003c\/li\u003e\n\u003cli\u003e48 x 1\/10\/25 Gigabit SFP28 + 8 x 40\/100 Gigabit QSFP28\u003c\/li\u003e\n\u003cli\u003eBack to front airflow\u003c\/li\u003e\n\u003cli\u003eRack-mountable\u003c\/li\u003e\n\u003cli\u003eDC Power Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n[properties]\n\u003ctable width=\"565\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003eJuniper EX4650-48Y-DC-AFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e48 25GbE\/10GbE\/GbE SFP28\/SFP+\/SFP ports, 8 100GbE\/40GbE QSFP28\/QSFP+ ports, redundant fans, 2 DC power supplies, 2 power cords, 4-post rack mount kit, and back to front airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4650 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e1.72 x 17.36 x 20.48 in (4.37 x 44.09 x 52.02 cm)\u003cbr data-mce-fragment=\"1\"\u003e Back-to-front (airflow in) for cold aisle deployment\u003cbr data-mce-fragment=\"1\"\u003e Management and console port connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e23.7 lb (10.75 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"565\" data-mce-fragment=\"1\"\u003eInterface Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e1GbE SFP\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e48 (24 copper 1GbE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e10GbE SFP+\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e48\/80 (with breakout cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e25GbE SFP28\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e48\/80 (with breakout cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e40GbE QSFP+\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e8 (Each QSFP+ port can be configured as a 4 x 10GbE interface or as a 40 Gbps port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e100GbE QSFP28\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e8 (Each QSFP28 port can be configured as a 4 x 25GbE interface or as a 100 Gbps port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"2\" width=\"200\" data-mce-fragment=\"1\"\u003e \u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"365\" data-mce-fragment=\"1\"\u003e1 USB 2.0 port\u003cbr data-mce-fragment=\"1\"\u003e 1 RS-232 console port\u003cbr data-mce-fragment=\"1\"\u003e 2 management ports: 2 x RJ-45 ports\u003cbr data-mce-fragment=\"1\"\u003e Supported transceiver and direct attach cable (DAC)\u003cbr data-mce-fragment=\"1\"\u003e SFP 1GbE optical and copper module\u003cbr data-mce-fragment=\"1\"\u003e SFP+ 10GbE optical modules\u003cbr data-mce-fragment=\"1\"\u003e SFP+ DAC cables: 1\/3 m twinax copper and 1\/3\/5\/7 m active twinax copper\u003cbr data-mce-fragment=\"1\"\u003e SFP28 DAC cables: 1 m twinax copper\u003cbr data-mce-fragment=\"1\"\u003e SFP28 optics: SR, LR\u003cbr data-mce-fragment=\"1\"\u003e QSFP+ DAC cables: 1\/3 m twinax copper\u003cbr data-mce-fragment=\"1\"\u003e QSFP+ optics: SR4, LX4, ESR4, ER4, LR4\u003cbr data-mce-fragment=\"1\"\u003e QSFP+ to SFP+ 10GbE direct attach breakout copper (1\/3 m twinax copper cable)\u003cbr data-mce-fragment=\"1\"\u003e QSFP28 to SFP28 25GbE direct attach breakout copper (1 m twinax copper cable)\u003cbr data-mce-fragment=\"1\"\u003e QSFP28 optics: SR4, ER4, PSM4, CWDM4, LR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax load 450 W; typical load 260 W; idle load 160 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eAirflow\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003eRedundant (N+1) and hot-pluggable fan modules for front-to-back and back-to-front airflow\u003cbr data-mce-fragment=\"1\"\u003e Redundant variable-speed fans to reduce power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003ePower Supply and Fan Modules\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003eDual redundant (1+1) and hot-pluggable 650 W AC\/DC power supplies\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e 110-240 V single phase AC power\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e -44 to -72 V DC power supply\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e Redundant (4+1) and hot-pluggable fan modules for front-to-back or back-to-front airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\n\u003ctable width=\"753\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eEX4650-48Y-DC-AFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e2 Tbps (unidirectional)\/4 Tbps (bidirectional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 2\/Layer 3 throughput (maximum with 64 byte packets)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e2976 Mpps (wire speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSwitching mode\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eCut-through and store-and-forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eRack Installation Kit\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eVersatile four post mounting options for 19-in server rack or datacom rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMAC addresses per system\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e288,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eVLAN Ids\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e4093\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eNumber of ports per LAG\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eNumber of link aggregation groups (LAGs)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMultiple Spanning Tree Protocol (MSTP) instances\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eVLAN Spanning Tree Protocol (VSTP) instances\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eFirewall filters\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eIngress filters: 1500\u003cbr data-mce-fragment=\"1\"\u003e Egress filters: 512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv4 unicast prefixes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e360,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv4 unicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e208,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv4 multicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e104,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eECMP paths\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv6 unicast prefixes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e170,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv6 unicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e104,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv6 multicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e52,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eARP entries\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e64,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eTraffic mirroring\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eMirroring destination ports per switch: 4\u003cbr data-mce-fragment=\"1\"\u003e Maximum number of mirroring sessions: 4\u003cbr data-mce-fragment=\"1\"\u003e Mirroring destination VLANs per switch: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eJumbo frame\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e9,216 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"753\" data-mce-fragment=\"1\"\u003eSoftware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eSTP—IEEE 802.1D (802.1D-2004)\u003cbr data-mce-fragment=\"1\"\u003e Rapid Spanning Tree Protocol (RSTP) (IEEE 802.1w); MSTP (IEEE 802.1s)\u003cbr data-mce-fragment=\"1\"\u003e Redundant Trunk Group (RTG)\u003cbr data-mce-fragment=\"1\"\u003e Bridge protocol data unit (BPDU) protect\u003cbr data-mce-fragment=\"1\"\u003e Loop protect\u003cbr data-mce-fragment=\"1\"\u003e Root protect\u003cbr data-mce-fragment=\"1\"\u003e RSTP and VSTP running concurrently\u003cbr data-mce-fragment=\"1\"\u003e VLAN—IEEE 802.1Q VLAN trunking\u003cbr data-mce-fragment=\"1\"\u003e The Routed VLAN Interface (RVI)\u003cbr data-mce-fragment=\"1\"\u003e Port-based VLAN\u003cbr data-mce-fragment=\"1\"\u003e Private VLAN (PVLAN)\u003cbr data-mce-fragment=\"1\"\u003e VLAN translation\u003cbr data-mce-fragment=\"1\"\u003e Static MAC address assignment for interface\u003cbr data-mce-fragment=\"1\"\u003e Per VLAN MAC learning (limit)\u003cbr data-mce-fragment=\"1\"\u003e MAC learning deactivate\u003cbr data-mce-fragment=\"1\"\u003e Link Aggregation and Link Aggregation Control Protocol (LACP) (IEEE 802.3ad)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 3 Features (IPv4)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003e Routing protocols (RIP, OSPF, IS-IS, BGP)\u003cbr data-mce-fragment=\"1\"\u003e Virtual Router Redundancy Protocol (VRRP)\u003cbr data-mce-fragment=\"1\"\u003e Bidirectional Forwarding Detection (BFD) protocol\u003cbr data-mce-fragment=\"1\"\u003e Virtual router\u003cbr data-mce-fragment=\"1\"\u003e Dynamic Host Configuration Protocol (DHCP) relay\u003cbr data-mce-fragment=\"1\"\u003e Proxy Address Resolution Protocol (ARP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMulticast Features\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eInternet Group Management Protocol (IGMP): v1, v2, v3\u003cbr data-mce-fragment=\"1\"\u003e IGMP snooping: v1, v2, and v3 (L2 only)\u003cbr data-mce-fragment=\"1\"\u003e IGMP Filter\u003cbr data-mce-fragment=\"1\"\u003e PIM-SM, PIM-SSM, PIM-DM\u003cbr data-mce-fragment=\"1\"\u003e Multicast Source Discovery Protocol (MSDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSecurity and Filters\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eSecure interface login and password\u003cbr data-mce-fragment=\"1\"\u003e RADIUS\u003cbr data-mce-fragment=\"1\"\u003e TACACS+\u003cbr data-mce-fragment=\"1\"\u003e Ingress and egress filters: Allow and deny, port filters, VLAN filters, and routed filters, including management port filters\u003cbr data-mce-fragment=\"1\"\u003e Filter actions: Logging, system logging, reject, mirror to an interface, counters, assign forwarding class, permit, drop, police, mark\u003cbr data-mce-fragment=\"1\"\u003e SSH v1, v2\u003cbr data-mce-fragment=\"1\"\u003e Static ARP support\u003cbr data-mce-fragment=\"1\"\u003e Storm control, port error deactivate, and autorecovery\u003cbr data-mce-fragment=\"1\"\u003e Sticky MAC address\u003cbr data-mce-fragment=\"1\"\u003e DHCP snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eL2 and L3 QoS: Classification, rewrite, queuing\u003cbr data-mce-fragment=\"1\"\u003e Rate limiting:\u003cbr data-mce-fragment=\"1\"\u003e -Ingress policing: Single-rate two-color policer, two-rate three-color policer\u003cbr data-mce-fragment=\"1\"\u003e -Egress policing: Policer, policer mark down action\u003cbr data-mce-fragment=\"1\"\u003e -Egress shaping: Per queue on each port\u003cbr data-mce-fragment=\"1\"\u003e 10 hardware queues per port (8 unicast and 2 multicast)\u003cbr data-mce-fragment=\"1\"\u003e Strict-priority queuing (PQ), shaped-deficit weighted round-robin (SDWRR), weighted random early detection (WRED), weighted tail drop\u003cbr data-mce-fragment=\"1\"\u003e FCoE Initialization Protocol (FIP) snooping\u003cbr data-mce-fragment=\"1\"\u003e 802.1p remarking\u003cbr data-mce-fragment=\"1\"\u003e L2 classification criteria: Interface, MAC address, Ethertype, 802.1p, VLAN\u003cbr data-mce-fragment=\"1\"\u003e Congestion avoidance capabilities: WRED\u003cbr data-mce-fragment=\"1\"\u003e Trust IEEE 802.1p (ingress)\u003cbr data-mce-fragment=\"1\"\u003e Remarking of bridged packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eVirtual Chassis\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e100GbE and 40GbE as Virtual Chassis port\u003cbr data-mce-fragment=\"1\"\u003e Virtual Chassis Routing Engine (RE) election\u003cbr data-mce-fragment=\"1\"\u003e Virtual Chassis pre-provisioning (plug-and-play)\u003cbr data-mce-fragment=\"1\"\u003e Auto-LAG formation of Virtual Chassis ports\u003cbr data-mce-fragment=\"1\"\u003e FCoE transit across Virtual Chassis members\u003cbr data-mce-fragment=\"1\"\u003e QoS on Virtual Chassis ports\u003cbr data-mce-fragment=\"1\"\u003e Local designated forwarding\u003cbr data-mce-fragment=\"1\"\u003e Graceful RE switchover (GRES)\u003cbr data-mce-fragment=\"1\"\u003e Nonstop routing (NSR)\u003cbr data-mce-fragment=\"1\"\u003e Nonstop bridging (NSB)\u003cbr data-mce-fragment=\"1\"\u003e Monitor distributed aggregate interface\u003cbr data-mce-fragment=\"1\"\u003e Control plane protection for virtual RE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eHigh Availability\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eBidirectional Forwarding Detection (BFD)\u003cbr data-mce-fragment=\"1\"\u003e Uplink failure detection\u003cbr data-mce-fragment=\"1\"\u003e Dynamic Load Balancing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eData Center Bridging (DCB)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003ePriority-based flow control (PFC)—IEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003e Data Center Bridging Capability Exchange (DCBX), DCBx FCoE, and iSCSI type, length, and value (TLVs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMPLS\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eStatic label-switched paths (LSPs)\u003cbr data-mce-fragment=\"1\"\u003e RSVP-based signaling of LSPs\u003cbr data-mce-fragment=\"1\"\u003e LDP-based signaling of LSPs\u003cbr data-mce-fragment=\"1\"\u003e LDP tunneling (LDP over RSVP)\u003cbr data-mce-fragment=\"1\"\u003e MPLS class of service (CoS)\u003cbr data-mce-fragment=\"1\"\u003e MPLS LSR support\u003cbr data-mce-fragment=\"1\"\u003e IPv6 tunneling (6PE) (via IPv4 MPLS backbone)\u003cbr data-mce-fragment=\"1\"\u003e IPv4 L3 VPN (RFC 2547, RFC 4364)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eDevice Management and Operations\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eRole-based CLI management and access\u003cbr data-mce-fragment=\"1\"\u003e CLI via console, telnet, or SSH\u003cbr data-mce-fragment=\"1\"\u003e Extended ping and traceroute\u003cbr data-mce-fragment=\"1\"\u003e OpenConfig for Junos OS to support the YANG data models\u003cbr data-mce-fragment=\"1\"\u003e Junos OS configuration rescue and rollback\u003cbr data-mce-fragment=\"1\"\u003e Image rollback\u003cbr data-mce-fragment=\"1\"\u003e SNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e Junos XML management protocol\u003cbr data-mce-fragment=\"1\"\u003e sFlow v5\u003cbr data-mce-fragment=\"1\"\u003e Beacon LED for port and system\u003cbr data-mce-fragment=\"1\"\u003e Zero Touch Provisioning (ZTP)\u003cbr data-mce-fragment=\"1\"\u003e OpenStack Neutron Plug-in\u003cbr data-mce-fragment=\"1\"\u003e Python\u003cbr data-mce-fragment=\"1\"\u003e Junos OS event, commit, and OP scripts\u003cbr data-mce-fragment=\"1\"\u003e Junos Telemetry Interface (JTI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eManagement and Analytics Platforms\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eJuniper Mist Wired Assurance for Campus\u003cbr data-mce-fragment=\"1\"\u003e Junos Space®Network Director for Campus\u003cbr data-mce-fragment=\"1\"\u003e Junos Space® Management \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eServer Virtualization Management and SDN-Related Protocols\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eVXLAN OVSDB\u003cbr data-mce-fragment=\"1\"\u003e EVPN-VXLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eMultichassis link aggregation (MC-LAG)\u003cbr data-mce-fragment=\"1\"\u003e EVPN Multihoming (ESI-LAG)\u003cbr data-mce-fragment=\"1\"\u003e LAG load-sharing algorithm—bridged or routed (unicast or multicast) traffic:\u003cbr data-mce-fragment=\"1\"\u003e -IP: SIP, Dynamic Internet Protocol (DIP), TCP\/UDP source port, TCP\/UDP destination port\u003cbr data-mce-fragment=\"1\"\u003e -L2 and non-IP: MAC SA, MAC DA, Ethertype, VLAN ID, source port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eTraffic Mirroring\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003ePort-based\u003cbr data-mce-fragment=\"1\"\u003e LAG port\u003cbr data-mce-fragment=\"1\"\u003e VLAN-based\u003cbr data-mce-fragment=\"1\"\u003e Filter-based\u003cbr data-mce-fragment=\"1\"\u003e Mirror to local\u003cbr data-mce-fragment=\"1\"\u003e Mirror to remote destinations (L2 over VLAN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 6000 ft (1829 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e5% to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIEEE Standards\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eIEEE standard\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1D\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1w\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1Q\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1p\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1ad\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3ad\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1AB\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3x\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1Qaz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eT11 Standards\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eINCITS T11 FC-BB-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSupported RFCs\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eRFC 768 UDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 783 Trivial File Transfer Protocol (TFTP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 791 IP\u003cbr data-mce-fragment=\"1\"\u003e RFC 792 ICMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 793 TCP\u003cbr data-mce-fragment=\"1\"\u003e RFC 826 ARP\u003cbr data-mce-fragment=\"1\"\u003e RFC 854 Telnet client and server\u003cbr data-mce-fragment=\"1\"\u003e RFC 894 IP over Ethernet\u003cbr data-mce-fragment=\"1\"\u003e RFC 903 RARP\u003cbr data-mce-fragment=\"1\"\u003e RFC 906 TFTP Bootstrap\u003cbr data-mce-fragment=\"1\"\u003e RFC 951 1542 BootP\u003cbr data-mce-fragment=\"1\"\u003e RFC 1058 Routing Information Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 1112 IGMP v1\u003cbr data-mce-fragment=\"1\"\u003e RFC 1122 Host requirements\u003cbr data-mce-fragment=\"1\"\u003e RFC 1142 OSI IS-IS Intra-domain Routing Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 1256 IPv4 ICMP Router Discovery (IRDP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1492 TACACS+\u003cbr data-mce-fragment=\"1\"\u003e RFC 1519 Classless Interdomain Routing (CIDR)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1587 OSPF not-so-stubby area (NSSA) Option\u003cbr data-mce-fragment=\"1\"\u003e RFC 1591 Domain Name System (DNS)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1745 BGP4\/IDRP for IP—OSPF Interaction\u003cbr data-mce-fragment=\"1\"\u003e RFC 1772 Application of the Border Gateway Protocol in the Internet\u003cbr data-mce-fragment=\"1\"\u003e RFC 1812 Requirements for IP Version 4 routers\u003cbr data-mce-fragment=\"1\"\u003e RFC 1997 BGP Communities Attribute\u003cbr data-mce-fragment=\"1\"\u003e RFC 2030 SNTP, Simple Network Time Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 2068 HTTP server\u003cbr data-mce-fragment=\"1\"\u003e RFC 2131 BOOTP\/DHCP relay agent and Dynamic Host\u003cbr data-mce-fragment=\"1\"\u003e RFC 2138 RADIUS Authentication\u003cbr data-mce-fragment=\"1\"\u003e RFC 2139 RADIUS Accounting\u003cbr data-mce-fragment=\"1\"\u003e RFC 2154 OSPF w\/Digital Signatures (Password, MD-5)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2236 IGMP v2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2267 Network ingress filtering\u003cbr data-mce-fragment=\"1\"\u003e RFC 2328 OSPF v2 (edge mode)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2338 VRRP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2362 PIM-SM (edge mode)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2370 OSPF Opaque link-state advertisement (LSA) Option\u003cbr data-mce-fragment=\"1\"\u003e RFC 2385 Protection of BGP Sessions via the TCP Message Digest 5 (MD5) Signature Option\u003cbr data-mce-fragment=\"1\"\u003e RFC 2439 BGP Route Flap Damping\u003cbr data-mce-fragment=\"1\"\u003e RFC 2453 RIP v2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2474 Definition of the Differentiated Services Field in the IPv4 and IPv6 Headers\u003cbr data-mce-fragment=\"1\"\u003e RFC 2597 Assured Forwarding PHB (per-hop behavior) Group\u003cbr data-mce-fragment=\"1\"\u003e RFC 2598 An Expedited Forwarding PHB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2697 A Single Rate Three Color Marker\u003cbr data-mce-fragment=\"1\"\u003e RFC 2698 A Two Rate Three Color Marker\u003cbr data-mce-fragment=\"1\"\u003e RFC 2796 BGP Route Reflection—An Alternative to Full Mesh IBGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2918 Route Refresh Capability for BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 3065 Autonomous System Confederations for BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3376 IGMP v3 (source-specific multicast include mode only)\u003cbr data-mce-fragment=\"1\"\u003e RFC 3392 Capabilities Advertisement with BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 3446, Anycast RP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3569 SSM\u003cbr data-mce-fragment=\"1\"\u003e RFC 3618 MSDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3623 Graceful OSPF Restart\u003cbr data-mce-fragment=\"1\"\u003e RFC 4271 Border Gateway Protocol 4 (BGP-4)\u003cbr data-mce-fragment=\"1\"\u003e RFC 4360 BGP Extended Communities Attribute\u003cbr data-mce-fragment=\"1\"\u003e RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 4486 Subcodes for BGP Cease Notification Message\u003cbr data-mce-fragment=\"1\"\u003e RFC 4724 Graceful Restart Mechanism for BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 4812 OSPF Restart Signaling\u003cbr data-mce-fragment=\"1\"\u003e RFC 4893 BGP Support for Four-octet AS Number Space\u003cbr data-mce-fragment=\"1\"\u003e RFC 5176 Dynamic Authorization Extensions to RADIUS\u003cbr data-mce-fragment=\"1\"\u003e RFC 5396 Textual Representation of Autonomous System (AS) Numbers\u003cbr data-mce-fragment=\"1\"\u003e RFC 5668 4-Octet AS Specific BGP Extended Community\u003cbr data-mce-fragment=\"1\"\u003e RFC 5880 Bidirectional Forwarding Detection (BFD) Dynamic Host Configuration Protocol (DHCP) server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSupported MIBs\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eRFC 1155 SMI\u003cbr data-mce-fragment=\"1\"\u003e RFC 1157 SNMPv1\u003cbr data-mce-fragment=\"1\"\u003e RFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like MIB and TRAPs\u003cbr data-mce-fragment=\"1\"\u003e RFC 1850 OSPFv2 MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 1901 Introduction to Community-based SNMPv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2011 SNMPv2 for Internet protocol using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2012 SNMPv2 for transmission control protocol using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2013 SNMPv2 for user datagram protocol using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2233, The Interfaces Group MIB Using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2287 System Application Packages MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2570 Introduction to Version 3 of the Internet-standard Network Management Framework\u003cbr data-mce-fragment=\"1\"\u003e RFC 2571 An Architecture for describing SNMP Management Frameworks (read-only access)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2572 Message Processing and Dispatching for the SNMP (read-only access)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2576 Coexistence between SNMP Version 1, Version 2, and Version 3\u003cbr data-mce-fragment=\"1\"\u003e RFC 2578 SNMP Structure of Management Information MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2579 SNMP Textual Conventions for SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2580 Conformance Statements for SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2665 Ethernet-like interface MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2787 VRRP MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2790 Host Resources MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2819 RMON MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2863 Interface Group MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2932 IPv4 Multicast MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 3410 Introduction and Applicability Statements for Internet Standard Management Framework\u003cbr data-mce-fragment=\"1\"\u003e RFC 3411 An architecture for describing SNMP Management Frameworks\u003cbr data-mce-fragment=\"1\"\u003e RFC 3412 Message Processing and Dispatching for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3413 Simple Network Management Protocol (SNMP) (all MIBs are supported except the Proxy MIB)\u003cbr data-mce-fragment=\"1\"\u003e RFC 3414 User-based Security Model (USM) for version 3 of SNMPv3\u003cbr data-mce-fragment=\"1\"\u003e RFC 3415 View-based Access Control Model (VACM) for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3416 Version 2 of the Protocol Operations for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3417 Transport Mappings for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3418 Management Information Base (MIB) for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3584 Coexistence between Version 1, Version 2, and Version 3 of the Internet-standard Network Management Framework\u003cbr data-mce-fragment=\"1\"\u003e RFC 3826 The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP User-based Security Model\u003cbr data-mce-fragment=\"1\"\u003e RFC 4188 Definitions of Managed Objects for Bridges\u003cbr data-mce-fragment=\"1\"\u003e RFC 4318 Definitions of Managed Objects for Bridges with Rapid Spanning Tree Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 4363b Q-Bridge VLAN MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSafety\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eCAN\/CSA-C22.2 No. 60950-1 Information Technology Equipment - Safety\u003cbr data-mce-fragment=\"1\"\u003e UL 60950-1 (2nd Edition) Information Technology Equipment – Safety\u003cbr data-mce-fragment=\"1\"\u003e EN 60950-1: 2006\/A2:2013 Information Technology Equipment – Safety\u003cbr data-mce-fragment=\"1\"\u003e IEC 60950-1: 2005\/A2:2013 Information Technology Equipment - Safety (All country deviations): CB Scheme\u003cbr data-mce-fragment=\"1\"\u003e EN 60825-1 Safety of Laser Products - Part 1: Equipment classification and requirements\u003cbr data-mce-fragment=\"1\"\u003e Federal Information Processing Standards (FIPS) 140-2 Support\u003cbr data-mce-fragment=\"1\"\u003e Network Device Collaborative Protection Profile (NDcPP) version 2.1 Common Criteria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eEMC\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eEN 300 386 V1.6.1 (2012-09) Electromagnetic compatibility and Radio spectrum Matters (ERM) Telecommunication network equipment\u003cbr data-mce-fragment=\"1\"\u003e EN 300 386 V2.1.1 (2016-07) Telecommunication network equipment; EMC requirements; Harmonized Standard covering the essential requirements of the Directive 2014\/30\/EU\u003cbr data-mce-fragment=\"1\"\u003e EN 55032:2012 (CISPR 32:2012) Electromagnetic compatibility of multimedia equipment—Emission requirements\u003cbr data-mce-fragment=\"1\"\u003e EN 55024:2010 (CISPR 24:2010) Information technology equipment—Immunity characteristics—Limits and methods of measurement\u003cbr data-mce-fragment=\"1\"\u003e IEC\/EN 61000 Immunity Test\u003cbr data-mce-fragment=\"1\"\u003e AS\/NZS CISPR 32:2015 Australia\/New Zealand Radiated and Conducted Emissions\u003cbr data-mce-fragment=\"1\"\u003e FCC 47 CFR Part 15 USA Radiated and Conducted Emissions\u003cbr data-mce-fragment=\"1\"\u003e ICES-003 Canada Radiated and Conducted Emissions\u003cbr data-mce-fragment=\"1\"\u003e VCCI-CISPR 32:2016 Japanese Radiated and Conducted Emissions\u003cbr data-mce-fragment=\"1\"\u003e BSMI CNS 13438 Taiwan Radiated and Conducted Emissions (at 10 Meters)\u003cbr data-mce-fragment=\"1\"\u003e KN32\/KN35 Korea Radiated Emission and Immunity Characteristics (at 10 Meters)\u003cbr data-mce-fragment=\"1\"\u003e KN61000 Korea Immunity Test\u003cbr data-mce-fragment=\"1\"\u003e TEC\/SD\/DD\/EMC-221\/05\/OCT-16 India EMC standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\n\u003ctable width=\"422\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"422\" data-mce-fragment=\"1\"\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJPSU-650W-DC-AFI\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eJuniper 650 W DC power supply (FRU-side to port-side airflow)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX5110-FANAFI\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eFANAFI fan model, back-to-front airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-4PST-RMK\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003e4 post rack mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eSoftware Feature Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX4650-PFL\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eEX4650 Premium Feature License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4650-AFL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4650 Advanced Feature License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"422\" data-mce-fragment=\"1\"\u003eOptics and Transceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-T\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-T copper transceiver module for up to 100 m transmission on Category 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-SX\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-SX GbE optics, 850 nm for up to 550 m transmission on multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-LX\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-LX GbE optics, 1310 nm for 10 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-USR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE ultra short reach optics, 850 nm for 10 m on OM1, 20 m on OM2, 100 m on OM3 multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-SR 10GbE optics, 850 nm for up to 300 m transmission on multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-LR 10GbE optics, 1310 nm for 10 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-ER\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-ER 10GbE optics, 1550 nm for 40 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-ZR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-ZR 10GbE optics, 1550 nm for 80 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-DAC-1M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE Direct Attach Copper (twinax copper cable), 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-DAC-3M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE Direct Attach Copper (twinax copper cable), 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-1MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE Direct Attach Copper (active twinax copper cable), 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-3MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE Direct Attach Copper (active twinax copper cable), 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-5MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE Direct Attach Copper (active twinax copper cable), 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-7MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE Direct Attach Copper (active twinax copper cable), 7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-SFPP-10GE-T\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ transceiver provides 100\/1000\/10000BASE-TX throughput up to 30m over a copper connection via an RJ-45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-25G-SR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP28 25GBASE-SR optics for up to 100 m transmission over serial multimode fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013261209817,"sku":"EX4650-48Y-DC-AFI-NEW","price":17436.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ex4650_6fce7ff9-e624-4194-b764-adfc5d8b76f2.jpg?v=1771852863","url":"https:\/\/www.aloinfousa.com.mx\/pt-br\/products\/juniper-ex4650-48y-dc-afi-switch-39by7","provider":"aloinfousa.com","version":"1.0","type":"link"}