{"product_id":"ge-b125-v3-patient-monitor","title":"GE B125 V3 Patient Monitor","description":"\u003cp\u003eThe GE B125 V3 Patient Monitor includes NIBP, IBP, Temperature, printer, 3 and 5 lead ECG, extension rack, and battery, as well as SpO\u003csub\u003e2\u003c\/sub\u003e.\u003c\/p\u003e\n\u003cp\u003eOPTIONAL CO2 MODULE From Drop Down Menu\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003e\u003cb\u003eNote:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eIBP Accessories Sold Separately.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWarranty:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1 Year.\u003c\/p\u003e\n\u003cp\u003eThe GE B125 V3 Patient Monitor is a portable multi-parameter unit designed to be used for monitoring, recording, and to generate alarms for multiple physiological parameters of adult, pediatric, and neonatal patients in a hospital environment and during intra-hospital transport.\u003c\/p\u003e\n\u003cp\u003eThe B125 Patient Monitor is able to detect and generate alarms for the following ECG arrhythmias: Asystole, Ventricular tachycardia, VT\u0026gt;2, Ventricular Bradycardia, Accelerated Ventricular Rhythm, Ventricular Couplet, Bigeminy, Trigeminy, “R on T”, Tachycardia, Bradycardia, Pause, Atrial Fibrillation, Multifocal PVCs, Missing Beat, Premature Ventricular Contraction (PVC and Ventricular fibrillation.\u003c\/p\u003e\n\u003ch4\u003eGE B125 V3 Patient Monitor Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSeven pre-configured workflow settings for simple set-up.\u003c\/li\u003e\n\u003cli\u003eAuto-snapshot of most critical alarms.\u003c\/li\u003e\n\u003cli\u003eAlarm reporting options for better alarm management and instant care in cases of arrhythmia, high\/low blood pressure, and ECG-lead detachment.\u003c\/li\u003e\n\u003cli\u003eConvenient screen lock button for easy cleaning, maintenance, and intra-hospital transport.\u003c\/li\u003e\n\u003cli\u003eCapacitive touchscreen for fast response and enhanced user experience.\u003c\/li\u003e\n\u003cli\u003eUninterrupted display of primary ECG-lead waveform and other vital signs across settings.\u003c\/li\u003e\n\u003cli\u003eChoice of numerical or continuous waveform monitoring.\u003c\/li\u003e\n\u003cli\u003eLarge numeric mode that enables critical parameter visibility even up to four meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eGE B125 V3 Patient Monitor Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e25 lb (11.3 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e18\" x 18\" x 18\" (45.7 cm x 45.7 cm x 45.7 cm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDisplay:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSize:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12.1\" (diagonal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eResolution:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1280 x 800 pixels (WVGA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNumber of Waveforms:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUp to 6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDisplay Layout and Colors:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUser-configurable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eControls:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCapacitive Touch Screen and Trim Knob control and hard keys (standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eECG:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eLeads Available:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e3-Lead Configuration:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eI, II, III.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e5-Lead Configuration:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eI, II, III, aVR, aVL, aVF, and V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSweep Speed:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12.5, 25, or 50 mm\/s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGain Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.5 x , 1 x, 2 x, and 4 x.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHeart Rate Accuracy:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e30 to 300 bpm, +\/- 5% or +\/-5 bpm, whichever is greater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e50\/60 Hz Power Supply:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMonitor:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.5 to 40 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eST:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.05 to 40 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDiagnostic:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.05 to 145 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePacemaker Detection:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eRange:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2 to 700 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePulse Width:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.5 to 2 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eArrhythmia Analysis:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAsystole, V Fib \/ V Tach, V Tach, VT\u0026gt;2 R on T, V Brady, Couplet, Bigeminy, Accelerated Ventricular arrhythmia, Multifocal PVCs, A Fib, Missing beat, Pause, Tachy, Brady, Trigeminy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eST Segment Analysis:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNumeric Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e-9 to +9 mm (-0.9 to +0.9 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAccuracy:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e+\/- 0.2 mm or +\/- 10%, whichever is greater, within the measurement range of -8 to 8 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNumeric Resolution:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.1 mm (0.01 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eST Trends:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUp to 168h.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRange:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAdult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e4 to 120 resp\/min.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e4 to 180 resp\/min.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAccuracy:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e+\/- 5% or +\/- 5 resp\/min, whichever is greater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGain Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.1 to 5 cm\/Ohm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpO\u003csub\u003e2\u003c\/sub\u003e:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eGE:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePulse Oximetry Measurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1 to 100%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePulse Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e30 to 250 bpm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSaturation Measurement Accuracy:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWithout Motion-Adult\/Pediatric Finger Sensor:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e70 to 100% +\/- 2%\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWithout Motion-Neonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e70 to 100% +\/- 3%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWith Motion-Adult\/Pediatric\/Neonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e70 to 100% +\/- 3%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLow Perfusion-Adult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e70 to 100% +\/-3% (1~69% unspecified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePulse Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eWithout Motion: +\/- 2 bpm (adult\/pediatric\/neonatal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNIBP:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement Technique:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eOscillometric with step deflation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModes:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eManual, Automatic, Stat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSystolic Measurement Range:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAdult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e30 to 290 mmHg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e30 to 260 mmHg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMAP Measurement Range:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAdult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e20 to 260 mmHg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e20 to 125 mmHg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDiastolic Measurement Range:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAdult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e10 to 220 mmHg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e10 to 110 mmHg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAccuracy:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eMeets AAMI ISO81060-2 and IEC 80601-2-30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDefault Initial Inflation Pressure:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAdult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e135 +\/- 15 mmHg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e100 +\/- 15 mmHg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum Determination Time:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAdult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2 min.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e100 +\/- 15 mmHg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOver Pressure Monitor:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eAdult\/Pediatric:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e294 +\/-6 to 330 mmHg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeonate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e147 +\/- 3 to 165 mmHg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInvasive Blood Pressure:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e-40 to 320 mmHg (15.3 to 42.7 kPa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement Accuracy;\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e+\/- 5% or +\/- 2 mmHg, whichever is greater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFrequency Response:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e4 to 22 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTransducer Sensitivity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e5 μV\/V\/mmHg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTemperature:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNumerical Display:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eT1, T2, T2-T1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e10 to 45 degrees C (50 to 113 degrees F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement Accuracy:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e+\/- 0.1 degrees C without probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDisplay Resolution:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.1 degrees C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProbe:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eYSI probes recommended by GE Healthcare.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EDAN","offers":[{"title":"Default Title","offer_id":48009601056985,"sku":null,"price":10200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ge-b125-v3-patient-monitor-468.webp?v=1771690152","url":"https:\/\/www.aloinfousa.com.mx\/sr\/products\/ge-b125-v3-patient-monitor","provider":"aloinfousa.com","version":"1.0","type":"link"}